5.7.23
STOP (stop TMCL™ program execution)
This function stops executing a TMCL™ program. The host address and the reply are only used to transfer
the instruction to the TMCL™ program memory.
This command should be placed at the end of every stand-alone TMCL™ program. It is not to be used
in direct mode.
Internal function:
TMCL™ instruction fetching is stopped.
Related commands:
none
Mnemonic:
STOP
Binary representation:
INSTRUCTION NO.
TYPE
MOT/BANK
VALUE
28
don’t care
don’t care
don’t care
Example:
Mnemonic:
STOP
Binary:
Byte Index
0
1
2
3
4
5
6
7
8
Function
Target-
address
Instruction
Number
Type
Motor/
Bank
Operand
Byte3
Operand
Byte2
Operand
Byte1
Operand
Byte0
Checksum
Value (hex)
$01
$1c
$00
$00
$00
$00
$00
$00
$1d