Using the RS485 interface
With most RS485 converters that can be attached to the COM port of a PC the data direction is controlled by
the RTS pin of the COM port. Please note that this will only work with Windows 2000, Windows XP or
Windows NT4, not with Windows 95, Windows 98 or Windows ME (due to a bug in these operating
systems). Another problem is that Windows 2000/XP/NT4 switches the direction back to
receive
too late. To
overcome this problem, set the
telegram pause time
(global parameter #75) of the module to 15 (or more if
needed) by issuing an
SGP 75, 0, 15
command in direct mode. The parameter will automatically be stored in
the configuration EEPROM.