![Trinamic PD57-1060 Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/trinamic/pd57-1060/pd57-1060_firmware-manual_1163104047.webp)
PD57/60-1060 / TMCM-1060 TMCL™ Firmware Manual (V1.04 / 2011-AUG-29)
47
Copyright © 2011, TRINAMIC Motion Control GmbH & Co. KG
Example:
Set the serial address of the target device to 3
Mnemonic:
SGP 66, 0, 3
Binary:
Byte Index
0
1
2
3
4
5
6
7
8
Function
Target-
address
Instruction
Number
Type
Motor/
Bank
Operand
Byte3
Operand
Byte2
Operand
Byte1
Operand
Byte0
Checksum
Value (hex)
$01
$09
$42
$00
$00
$00
$00
$03
$4f