PD57/60-1060 / TMCM-1060 TMCL™ Firmware Manual (V1.04 / 2011-AUG-29)
100
Copyright © 2011, TRINAMIC Motion Control GmbH & Co. KG
7
Global parameters
Global parameters are grouped into 4 banks:
bank 0 (global configuration of the module)
bank 1 (user C variables)
bank 2 (user TMCL™ variables)
bank 3 (interrupt configuration)
Please use SGP and GGP commands to write and read global parameters.
7.1
Bank 0
Parameters with numbers from 64 on configure stuff like the serial address of the module RS485 baud rate
or the CAN bit rate. Change these parameters to meet your needs. The best and easiest way to do this is to
use the appropriate functions of the TMCL-IDE. The parameters with numbers between 64 and 128 are stored
in EEPROM only.
An SGP command on such a parameter will always store it permanently and no extra STGP command
is needed.
Take care when changing these parameters, and use the appropriate functions of the TMCL-IDE to do it
in an interactive way.
Meaning of the letters in column
Access
:
R = readable (GGP)
W = writeable (SGP)
E = automatically restored from EEPROM after reset or power-on.
Note: The TMCM-1060 does not have the parameters 0…38. They are used for modules which address more
than one motor.
Number Global parameter
Description
Range
Access
64
EEPROM magic
Setting this parameter to a different value as $E4 will
cause re-initialization of the axis and global parameters
(to factory defaults) after the next power up. This is
useful in case of miss-configuration.
0… 255
RWE
65
RS485 baud rate
0
9600 baud (default)
1
14400 baud
2
19200 baud
3
28800 baud
4
38400 baud
5
57600 baud
6
76800 baud
Not supported by Windows!
7
115200 baud
8
230400 baud
9
250000 baud
Not supported by Windows!
10
500000 baud
Not supported by Windows!
11
1000000 baud
Not supported by Windows!
0… 11
RWE
66
serial address
The module (target) address for RS-485.
0… 255
RWE