Number Axis Parameter
Description
12
right limit switch
disable
1=right stop switch disabled
0=right stop switch enabled
13
left limit switch
disable
1=left stop switch disabled
0=left stop switch enabled
128
ramp mode
Automatically set when using ROR, ROL, MST
and MVP.
0: position mode. Steps are generated, when
the parameters actual position and target
position differ. Trapezoidal speed ramps are
provided.
1: velocity mode. The motor will run
continuously and the speed will be changed
with constant (maximum) acceleration, if the
parameter target speed is changed.
140
microstep
resolution
0
full step
1
half step
2
4 microsteps
3
8 microsteps
4
16 microsteps
5
32 microsteps
6
64 microsteps
7
128 microsteps
8
256 microsteps
160
step interpolation
enable
Step interpolation is supported with a 16
microstep setting only. In this setting, each
step impulse at the input causes the
execution of 16 times 1/256 microsteps. This
way, a smooth motor movement like in 256
microstep resolution is achieved.
0 – step interpolation off
1 – step interpolation on
161
double step
enable
Every edge of the cycle releases a
step/microstep.
It does not make sense to
activate this parameter
for internal use.
Double step enable can be used with Step/Dir
interface.
0 – double step off
1 – double step on
162
chopper blank
time
Selects the comparator
blank time
. This time
needs to safely cover the switching event and
the duration of the ringing on the sense
resistor. For low current drivers, a setting of 1
or 2 is good. For higher current applications
like the TMCM-1060 a setting of 2 or 3 will be
required.
163
chopper mode
Selection of the chopper mode:
0 – spread cycle
1 – classic const. off time
164
chopper
hysteresis
decrement
Hysteresis decrement setting. This setting
determines the slope of the hysteresis during
on time and during fast decay time.
0 – fast decrement
3 – very slow decrement