Communication
TCD Electronics | Function Manual | Version: TCD_PROFI_S_EN_200326_E003
25
Index Parameter name
Data type
[size]
Access Annotation
127
FRACTION_FLOW_
B
101
Read
only
128
FRACTION_FLOW_
UNITS
Unsigned16 Read
Write
Selected unit for fractional mass flow value that
affects values accessed via the PROFIBUS fieldbus
interface.
The coding is according the PROFIBUS PA Profile
specification:
1318: g/s
1319: g/min
1320: g/h
1321: g/d
1322: kg/s
1323: kg/min
1324: kg/h
1325: kg/d
1326: t/s
1327: t/min
1328: t/h
1329: t/d
1330: lb/s
1331: lb/min
1332: lb/h
1333: lb/d
1334: STon/s
1335: STon/min
1336: STon/h
1337: STon/d
1338: T/s
1339: T/min
1340: T/h
1341: T/d
1606: oz/s
1607: oz/min
1608: oz/h
1609: oz/d
1995: customized unit
Selected unit for fractional volume flow value that
affects values accessed via the PROFIBUS fieldbus
interface.
The coding is according the PROFIBUS PA Profile
specification:
1347: m³/s
1348: m³/min
1349: m³/h
1350: m³/d
1351: l/s
1352: l/min
1353: l/h