8.0  Normal functioning sequence in the 4 installation modes 

 

The EG-3 in HARDWIRE mode is always armed.  When it receives a trigger from the installed  hardwire control 
panel, an  SMS message will be sent and an alarm trigger  will be sent  to  the indoor or  outdoor  wireless siren.  
After  this  the  onboard PIR sensor  will become active  and  any violation  of its protected  area, the EG-3HW will 
transmit the images captured, however, if after 4 min. no movement is detected, no images will be sent and the 
EG-3HW onboard PIR sensor will return to standby. 

 

The  EG-3 in WIRELESS mode is armed and disarmed by the wireless control panel installed. The EG-3WL  will 
emit a beep when it is armed and 2 beeps when disarmed. The slave sensors installed with the “Pegaso” wire-
less control panel will trigger the panel. The panel will then trigger the EG-3WL  and, if installed, also the outdoor 
wireless siren. The EG-3WL  will send first the  personalized SMS messages  to  4 memorized telephone  num-
bers,  then  the  onboard  PIR  will  become  active  and  if  violated  will  transmit  by  MMS  to  the  same  4  telephone 
numbers and to 2 E-mail addresses the images of the protected area. After 4 min. if no movement is detected, 
no images will be sent and  the EG-3WL onboard PIR sensor will return to stand-by mode. 

  

The  EG-3 in STAND-ALONE  mode is armed and disarmed by the keychain transmitter PEG-3.    When armed, 
the EG-3SL will emit 1 beep and when disarmed 2 beeps. The units onboard PIR sensor will become active af-
ter a 25 second exit time and when violated will send first the SMS trigger message and also trigger the indoor 
and outdoor wireless siren followed by the images of the protected area to the memorized telephone numbers 
and E-mail addresses. 

 

The EG-3 in the STAND-ALONE  MASTER  mode is armed  and  disarmed  by the keychain  transmitter PEG-3
When it is armed the unit will emit 1 beep and when disarmed 2 beeps.  The EG-3SLM will become active after 
a  25 second exit time  and after it  has receive  an alarm trigger form  one of the   installed slave sensors, it  will 
send first  the SMS alarm trigger message  and  also trigger the indoor and  outdoor wireless siren and then the 
EG-3SLM onboard PIR sensor  will become active  and, if violated,  will send the MMS images to the  4 memo-
rized telephone number and E-mail addresses.  After 4 min. if no movement is detected, no images will be sent 
and the EG-3SLM onboard PIR   sensor will return to stand-by mode. 

 

The EG-3 will perform the following functions

1.  Sends 1 of the 3 memorized alarm trigger messages (Burglary, Fire and Panic or Medical). 
2.  Sends in case of a Tamper alarm trigger from any sensor an SMS message “Tamper Alarm” 
3.  If armed, sends, in case of a sensor with a low battery, an SMS indicating “Low Battery” of the sensor that 

has transmitted the alarm trigger followed by an SMS with the alarm trigger message. 

4.  When the EG-3  is disarmed, if a sensor has a low battery the EG-3  will inform the end user with an SMS 

“Low Battery” message.  No alarm trigger will take place. 

5.  Sends an alarm trigger transmission to the indoor and outdoor wireless siren. 
6.  Sends MMS images to the memorized telephone numbers and E-mail addresses. 
7.  Memorize an additional 32 images on the onboard micro SD card. 
 

8.1  Listen-in and 2 way communication functions  

 

It is possible to operate these 2 functions only when the EG-3 is armed and only from the 1st 
memorized telephone number which is considered the Master Number.
 
If the master number calls the EG-3,  the  unit  will  hangs  up  immediately,  the  EG-3  will call the 
master  number  back  and  when the phone is  answered the EG-3  will  automatically  go  into  listen-in 
mode. If the master number operator chooses to go into 2 way communication, he must press the # 
key on his telephone.  
 

8.2  EG-3 real time control of the protected area  

By sending simple SMS command  messages,  allows  you to have real time control  of the  area  you 
wish to  protect  and  at  the same time  allows  you to change the function  of  how this  areas  must be 
protected. You have also the possibility to change the state of an on-board dry contact relay that may 
be use for home automation or to arm/disarm the security system (See sections 3.1 and 7.0). 

Page 35 

EG-3 Instruction manual 

ENGLISH 

Содержание EG-3

Страница 1: ...TRASMISSIONE SMS MMS e E con TRASMISSIONE SMS MMS e E con TRASMISSIONE SMS MMS e E mail mail mail mail MULTIFUNCTION SECURITY SYSTEM with MULTIFUNCTION SECURITY SYSTEM with MULTIFUNCTION SECURITY SYS...

Страница 2: ...rizing EG 3 to function in mode EG 3WL 27 EG 3SL STAND ALONE 5 0 Installation of EG 3 to function in mode EG 3SL 28 5 1 Activation and memorizing the Pegaso codes in the EG 3SL 29 EG 3SLM STAND ALONE...

Страница 3: ...nds SMS message of Tamper and Low Battery In this mode a full wireless installation can be made without having to install another control panel The EG 3 in EG 3SLM mode becomes your control panel tele...

Страница 4: ...t Swivel bracket Speaker SIM card holder Dip switch Battery connection On Off switch Reset and sensor self learning button Blue LED indicator Hardwire terminal Micro USB connector 1 2 3 4 CMOS Camera...

Страница 5: ...or that are over heated PIR WORKING RANGE The EG 3 must be installed at a height of 2 00 to 2 20 meters in order that the PIR sensor may have a minimum range of 0 40 meters and maximum range of 12 00...

Страница 6: ...0 2 2 Functional LED Indicators The LEDS positioned on the right of the EG 3 see page 4 have the following functions The LED 1 indicates the Power and GPRS GSM field presence When the EG 3 is powered...

Страница 7: ...roof keychain transmitter PEG 1 supplied optional If the burglary fire or panic alarm is triggered the programmed SMS message will be sent to the 4 memorized telephone numbers After the SMS message is...

Страница 8: ...eal time the alarm that has been triggered Burglary Fire Panic or Medical Distress You must note that in the mode EG 3HW it is not possible to silence the siren once the alarm is trigger The siren wil...

Страница 9: ...3WL from the Pegaso wireless control panel Burglary Fire or Panic the EG 3WL will send to the 4 memorize telephone numbers the SMS message memorized for the event triggered After the SMS message has b...

Страница 10: ...el 1 The control panel must have the option of using a wireless siren selected as YES 2 Arm the control panel with the keychain transmitter and immediately after press the RESET LEARN button of the EG...

Страница 11: ...ive and if triggered an SMS alarm message will be sent to the 4 memorized telephone numbers and an R F alarm trigger signal will be sent to the outdoor wireless siren Immediately after the SMS message...

Страница 12: ...orized on board TO MEMORIZE A PEGASO WIRELESS SIREN To code a wireless Pegaso outdoor siren with the EG 3SL follow the programming instructions in section 5 0 supplied with the siren In this mode it i...

Страница 13: ...less Pegaso series siren and a memorized SMS message to 4 memorized telephone numbers The EG SLM on board PIR SENSOR will then become active and if triggered will send to the same 4 telephone numbers...

Страница 14: ...d The memory has been cancelled This means that all sensors and keychain transmitters previously self learned have been cancelled from the memory TO MEMORIZE A WIRELESS PEGASO SIREN WITH THE EG 3SLM T...

Страница 15: ...ive the sms indicates the end of the SMS message The EG 3 will send an SMS confirmation Program the SIM card to send MMS image transmissions Format Password EG 3 GG http page ip address port APN user...

Страница 16: ...nd format EG 3 Password DM02 SMS text of max 64 characters Panic or Medical distress alarm mess command format EG 3 Password DM03 SMS text of max 64 characters Example 0000DM01 Burglary at TRE I Syste...

Страница 17: ...0 is the Password CM is the command indicates end of SMS The EG 3 will send an SMS confirmation message EG 3HW or EG 3W or EG 3SL or EG 3SLM Request of EG 3 status This will not function in mode EG 3H...

Страница 18: ...the installed slave sensors it will send first the SMS alarm trigger message and also trigger the indoor and outdoor wireless siren and then the EG 3SLM onboard PIR sensor will become active and if v...

Страница 19: ...ve technical assistance on the EG 3 PRODUCT SECURITY The EG 3 is not water proof and can not be installed outdoors and even if installed indoors we suggest to use in a dry area Avoid high humidity are...

Страница 20: ...provements on the present product without previous notice TRE i SYSTEMS TRE i SYSTEMS TRE i SYSTEMS TRE i SYSTEMS declines any responsibility for not observing the local laws in force La TRE i SYSTEMS...

Отзывы: