background image

PROGRAMMING & COMMANDS 

 

7.0  Programming and setting of SMS command messages 

 

The EG-3, in all 4 modes, can memorize:  3 Personalized 64 character SMS messages one for 
BURGLARY, one for FIRE and one for PANIC or MEDICAL DESTRESS alarm,  4  Telephone  num-
bers  and  2  E-mail  addresses
.  To achieve this the EG-3  must be powered up and from a normal 
cellular telephone, you must send SMS  command messages as indicated below. 
The first memorized telephone number is classified as the (MASTER NUMBER).

 

 

General Information: 

Factory installed password : 0000 
Personalize 64 character SMS messages:  DM-01 Burglary, DM-02 Fire, DM-03 Panic or Medical. 
Telephone number positions: A1,  A2,  A3,  A4  
Positions of E-mail addresses:  A5,  A6

 

 

       To memorize in the EG-3 a telephone number for the transmission of SMS & MMS data: 

Command format: Pa position  international code + telephone  #

 

 

Example: 393381234567#     0000  is the password,  A1 is  tel.  number  position,  +39 is the 
country international code, 3381234567 is the telephone number that must receive the sms,  
#  indicates the end of the SMS message. The EG-3 will send an SMS confirmation. 

 

                             Program the SIM card to send MMS image transmissions: 

             Format: Password EG-3+GG+http page+ip address:port+APN,user name, p#

 

The EG-3 will send an SMS confirmation: “GPRS okay” or “GPRS not okay” 

 

Below you will find GPRS CONFIGURATIONS most used by the ITALIAN GSM PROVIDERS. 

 

  Gsm provider TIM-Telecom Italia Mobile 

  

0000GGhttp://mms.tim.it/servlets/mms:;213.230.130.89:;mms.tim.it,,;#

 

 

  

Gsm provider VODAFONE-ITALIA

 

  

0000GGhttp://mms.vodafone.it/servlets/mms:;10.128.224.10:;mms.vodafone.it,,;#

 

 

  

Gsm provider WIND-ITALIA

 

  

0000GGhttp://mms.wind.it:;212.245.244.11:;mms.wind,,;#

 

 

IMPORTANT:  All symbols, punctuation marks and spaces must be included. Also note that the user name and 
password have been omitted. If there are any doubts or if you wish to use another GSM server, you must contact 
them directly for explanations on how the SIM CARD must be configured.  Parameters to know are the following: 

Server: 

GPRS NET 

Homepage: 

http://mms.tim.it/servlets/mms 

IP address: 

213.230.130.89 

IP port: 

 

APN: 

mms.tim.it 

User name: 

 

Password: 

 

 

Example of GPRS NET (in this case TIM server) 

http://mms.tim.it/servlets/mms:;213.230.130.89:;mms.tim.it,,;

 

Page 32 

EG-3 Instruction manual 

ENGLISH 

Содержание EG-3

Страница 1: ...TRASMISSIONE SMS MMS e E con TRASMISSIONE SMS MMS e E con TRASMISSIONE SMS MMS e E mail mail mail mail MULTIFUNCTION SECURITY SYSTEM with MULTIFUNCTION SECURITY SYSTEM with MULTIFUNCTION SECURITY SYS...

Страница 2: ...rizing EG 3 to function in mode EG 3WL 27 EG 3SL STAND ALONE 5 0 Installation of EG 3 to function in mode EG 3SL 28 5 1 Activation and memorizing the Pegaso codes in the EG 3SL 29 EG 3SLM STAND ALONE...

Страница 3: ...nds SMS message of Tamper and Low Battery In this mode a full wireless installation can be made without having to install another control panel The EG 3 in EG 3SLM mode becomes your control panel tele...

Страница 4: ...t Swivel bracket Speaker SIM card holder Dip switch Battery connection On Off switch Reset and sensor self learning button Blue LED indicator Hardwire terminal Micro USB connector 1 2 3 4 CMOS Camera...

Страница 5: ...or that are over heated PIR WORKING RANGE The EG 3 must be installed at a height of 2 00 to 2 20 meters in order that the PIR sensor may have a minimum range of 0 40 meters and maximum range of 12 00...

Страница 6: ...0 2 2 Functional LED Indicators The LEDS positioned on the right of the EG 3 see page 4 have the following functions The LED 1 indicates the Power and GPRS GSM field presence When the EG 3 is powered...

Страница 7: ...roof keychain transmitter PEG 1 supplied optional If the burglary fire or panic alarm is triggered the programmed SMS message will be sent to the 4 memorized telephone numbers After the SMS message is...

Страница 8: ...eal time the alarm that has been triggered Burglary Fire Panic or Medical Distress You must note that in the mode EG 3HW it is not possible to silence the siren once the alarm is trigger The siren wil...

Страница 9: ...3WL from the Pegaso wireless control panel Burglary Fire or Panic the EG 3WL will send to the 4 memorize telephone numbers the SMS message memorized for the event triggered After the SMS message has b...

Страница 10: ...el 1 The control panel must have the option of using a wireless siren selected as YES 2 Arm the control panel with the keychain transmitter and immediately after press the RESET LEARN button of the EG...

Страница 11: ...ive and if triggered an SMS alarm message will be sent to the 4 memorized telephone numbers and an R F alarm trigger signal will be sent to the outdoor wireless siren Immediately after the SMS message...

Страница 12: ...orized on board TO MEMORIZE A PEGASO WIRELESS SIREN To code a wireless Pegaso outdoor siren with the EG 3SL follow the programming instructions in section 5 0 supplied with the siren In this mode it i...

Страница 13: ...less Pegaso series siren and a memorized SMS message to 4 memorized telephone numbers The EG SLM on board PIR SENSOR will then become active and if triggered will send to the same 4 telephone numbers...

Страница 14: ...d The memory has been cancelled This means that all sensors and keychain transmitters previously self learned have been cancelled from the memory TO MEMORIZE A WIRELESS PEGASO SIREN WITH THE EG 3SLM T...

Страница 15: ...ive the sms indicates the end of the SMS message The EG 3 will send an SMS confirmation Program the SIM card to send MMS image transmissions Format Password EG 3 GG http page ip address port APN user...

Страница 16: ...nd format EG 3 Password DM02 SMS text of max 64 characters Panic or Medical distress alarm mess command format EG 3 Password DM03 SMS text of max 64 characters Example 0000DM01 Burglary at TRE I Syste...

Страница 17: ...0 is the Password CM is the command indicates end of SMS The EG 3 will send an SMS confirmation message EG 3HW or EG 3W or EG 3SL or EG 3SLM Request of EG 3 status This will not function in mode EG 3H...

Страница 18: ...the installed slave sensors it will send first the SMS alarm trigger message and also trigger the indoor and outdoor wireless siren and then the EG 3SLM onboard PIR sensor will become active and if v...

Страница 19: ...ve technical assistance on the EG 3 PRODUCT SECURITY The EG 3 is not water proof and can not be installed outdoors and even if installed indoors we suggest to use in a dry area Avoid high humidity are...

Страница 20: ...provements on the present product without previous notice TRE i SYSTEMS TRE i SYSTEMS TRE i SYSTEMS TRE i SYSTEMS declines any responsibility for not observing the local laws in force La TRE i SYSTEMS...

Отзывы: