EG-3SL (STAND-ALONE)
5.0 installation of EG-3 to function in mode EG-3SL
In this mode the EG-3SL will functions as a stand-alone control unit and will
protect a single area. Make sure that the “on/off” switch located in the battery
compartment is in “OFF” position. Set the dip-switch located in the back-up
battery compartments as shown in fig. 4 to the right. Once set, the EG-3SL
must be initialized. Connect the power supply cables based on the polarity to
the terminals 1 and 2 as shown in section 3.1. and plug it into the mains. Press
continuously the RESET/LEARN button located in the battery compartment and
switch to “ON” position the “on/off” switch. After 8 seconds the EG-3SL will
emit 3 beeps. Release the RESET/LEARN button and after another 45 se-
conds an additional 2 beeps will be heard. This confirms that the EG-3SL has
been successfully initialized.
Note: During this initialization period the RED LED (1) will light and immediately
after. If GPRS signal is present this same led become green.
To arm and disarm the EG-3SL it is necessary to program at least one PEG-3 keychain transmitter
(see section 5.1). To arm press the button on the upper left of the PEG-3. The EG-3SL will emit 1
beep and after an exit time of 25 seconds, it will be fully armed. To disarm you must press the same
button and 2 beeps are emitted. This indicates that the EG-3 has been disarmed.
Once the EG-3SL is armed, the on-board PIR becomes active and if triggered, an SMS alarm
message will be sent to the 4 memorized telephone numbers and an R.F. alarm trigger signal will be
sent to the outdoor wireless siren.
Immediately after the SMS message is sent the EG-3SL will proceed to send 5 images of the
protected area to the same 4 telephone numbers and to 2 E-mail addresses.
How to program the SMS messages, telephone numbers and E-mail addresses can be seen in
section 7.0.
In addition the EG-3SL will memorize 32 images on a micro SD card which must be removed from
the unit and placed into an SD card reader to view.
With remote SMS commands, it is possible to request from the EG-3SL in armed status:
1. To change, for 5 seconds, the state of the on-board relay contact, outputs (COM, NO, NC).
May be used to arm/disarm the control panel or for home automation (see section 3.1).
2. To enter into listen-in or two way communication function and hear what is taking place in the
protected area (see section 8.1).
3. To request that images be sent as periodic control of the protected area (see section 7.0).
4. To change the memorized telephone numbers and E-mail addresses (see section 7.0).
Once the EG-3SL is triggered, it will send first the memorized SMS message indicating the type of
alarm triggered (Burglary, Fire or Panic/Medical Distress). It will send also send a radio signal
transmission to the indoor or outdoor siren, if installed, that will sound based on the trigger signal
received. The EG-3SL will then proceed to send the MMS and E-MAIL images to the memorized tel-
ephone numbers and e-mail addresses.
1 2 3 4
Fig. 5
MODALITA’ SL
+
-
Page 28
EG-3 Instruction manual
ENGLISH