![TRE i SYSTEMS Dualcom-8 Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/tre-i-systems/dualcom-8/dualcom-8_installation-manual_1154736060.webp)
Pag. 60
DUALCOM-8 INSTALLATION MANUAL
ENGLISH
17 Visualizing the ARM/DISARM event log
In this section, you may visualize the events of all arming and disarming of the control panel with the
time, date, operator and how the control panel has been armed.
In the programming menu press the digits:
On the Display will appear:
In this mode you may:
1. Visualize the memory log of the last 40 Arming.
Note: When the ARM memory log full (over 40), the older arming will be automaticly cancelled
and the last arming will be automatically memorized in the log.
On your Keypad press the digits:
【
01
】
+
【
#
】
or flow up and down in the menu with the keys:
【
】
or
【
】
On the Display appears:
In the above example the operator 2 has Armed the Dualcom-8 in DAY mode on 22 Febuary at 18:15
Arm record
Arm record
<01>0201202221815
Description
Note
Operator
From 01 to 08 .In this
case, Operator
02
.
Arming mode
01 = DAY
02 =
NIGHT
03 =
OFF
Month
From 01 to 12. In this
case,
Febuary
.
Day
From 01 to 31. In this
case,
Day 22
.
Hour
From 00 to 23.
In questo caso
18.
Minutes
From 00 to 59 in this
case,
15 minutes
.
Position
In this case, the last
event.
【
】+【
17
】+【#】