Pag. 23
DUALCOM-8 INSTALLATION MANUAL
ENGLISH
After having installed sensors in each zone and after making sure that this installation has been done
correctly, set the parameters of each zone and at the end press the
【
#
】
key to confirm. In case of
doubts, it is best to repeat the programming sequence rather than risk malfunction of the panel.
Example of wireless zone settings:
Zone 25 must be sent for:
1. (5) Burglary Alarm
2. (1) Zone must be controller by Arm/Disarm
3. (0) Zone must be immediate
4. (1) Outdoor Hardwired siren armed
5. (1) Type of siren alarm sound
6. (1) Keypad pre-alarm buzzer in function
7. (1) Panel set for night mode
8. (0) No signal from panel of low battery sensor
9. (0) Alarm set for the Area 1 trigger only
Setting on the display must be as shown below:
After setting is terminated press
【
#
】
to confirm.
04.02 Setting of wireless zone 26 to 72 follow procedure below:
In the menu for the management of the hardwire zones
,
press the digits:
【
(26-72)
】
+
【
#
】
Go up and down with the keys:
【
】
or
【
】
Follow the setting indications shown in section 04.01.
Carefully digit on keypad the programming sequence and at the end press the
【
#
】
key to confirm.
Wireless zone
<25>510111100