Pag. 19
DUALCOM-8 INSTALLATION MANUAL
ENGLISH
03.01 Graphic design showing hardwire zone management
While in the menu for the hardwire zone management
,
press digits
【
01
】
+
【
#
】
or go up or down with:
【 】
or
【 】
0 24
hour
[1]
Panel Armed
(
2
) ZONE TYPE
Wired zone
<01>5102000210
LIV Description
Contact
ID
0
Medical Distress Alarm
100
1 Fire
Alarm
110
2 Gas
Alarm
111
3 Panic
Alarm
120
4 Hold-up
Alarm
121
[5]
Burglary Alarm
130
6 Parametric
Alarm
131
7 Flood
Alarm
154
(
1
) TIPE OF ALARM
8 Pull
Station
115
9 Tamper
Alarm
144
[0]
Immediate
1 Delayed
(
3
) TIME
(
4
) TYPE OF OUTDOOR
SIREN
0
No Siren Installed
1 Hardwire
Siren
[2]
Wireless Siren
3
Hardwire & Wireless
(
5
) TYPE OF SIREN SOUND
[0]
Burglary (continuous)
1
Hold-up (silent or sounding)
2 Fire
(bell
sound)
(
6
) KEYPAD BUZZER
[0]
NO Sound when Triggered
1
With Sound if Triggered
(
7
) DAY AND NIGHT MODES
[0]
Armed in Day mode
1
Armed in Night mode
(
8
) RESPONSE TIME
0 0-55
ms
1 1-250
ms
[2]
2-500 ms
3 3-750
ms
(
9
) TYPE OF CONTACT
0 Normally
open
(1)
Normally closed
2 Line
unbalanced*
(
10
) ASSOCIATATE TO
[0]
AREA 1
1
AREA 2
ZONE no.
** It is necessary to
insert the supplied
4k7
Ω
resistor
in series
with the sensor. By un
balancing this line an
alarm trigger will take
place