TransVu Compact
52
Basic
This menu allows the configuration of active camera channels.
Camera Nuisance Count If a camera is intermittantly losing connection (failing). The unit can be set to
ignore incoming data from that camera (after the specified number of failures
entered here). If the camera connection is restored and does not fail for 1 hour,
the camera wil be noted as operating correctly and the Nuisance Count reset.
Title
Each of the camera titles can be edited for ease of use i.e. the camera type,
location or view description could be used.
Note: If a camera title is entered via the local monitor, an on-screen virtual keyboard will be displayed to
aid text entry.
Mode
The settings will default to ‘Colour’. If Monochrome cameras are used, select
‘Mono’. Selecting ‘Mono’ will remove colour patterning. If a particular channel is
not in use or the camera has failed, select ‘Not Connected’.
Term
Cameras that are not being looped through to another piece of equipment will
need to be terminated. Double termination (not removing termination from the
unit) will result in the 1V peak to peak video signal being crushed. This can
reduce the colour rendition of the video source and may cause the video signal
not to be detected by the last piece of equipment i.e. the signal is no longer 1V
peak-to-peak.
Fail Rep
Select this option to activate a Failure report in the event of camera connection
failure.
Note: The arrow button displayed next to each textbox allows settings to be replicated for those cameras
listed below. This will only affect the adjacent option i.e. Mode arrow will replicate the Mode setting