TransVu Compact
28
Power Manager
This menu allows configuration of power management and ignition line control functions.
Power Management
Select ‘Enabled’ to activate all configured Power
Management functions.
Powerman Version
Details the version number of the installed Powerman controller
software.
Ignition Off Timeout
Enter a time (in seconds) from the ignition being switched Off to the unit
powering down.
Low Supply Timeout
Enter a time (in seconds) from a low voltage supply being detected to the unit
powering down.
Minimum Supply
Enter the minimum voltage level at which the unit will commence a forced
shutdown.
Nominal Supply
Enter the nominal voltage at which the Low Supply Timeout function will
activate.
Ignition Enabled
Select ‘Enabled’ to activate the ignition timeout control.
Ignition Threshold
Enter the minimum ignition voltage required to start the unit up.
12v Output
Enable/disable the 12v output supply from the unit