21
KEYBOARD
The keyboard is composed of a total of twenty-four (24) keys. There are twelve (12) function keys and
twelve (12) numeric keypad keys.
FUNCTION KEYS
UNITS – This key toggles the indicator among lb, kg and third unit if enabled in the Setup
(“F”) menu.
ZERO - This key sets the indicator to display zero as long as the following conditions are met:
1. The indicator is displaying Gross weight.
2. The displayed weight is within the zero reset range that is programmed in F4 of the Setup
(“F”) Menu.
3. The scale is not in motion.
4. The scale is not in overload (see Appendix D for error codes).
MODE – If a system Tare has been established, this key toggles the display among Gross
weight, Net weight and Tare weight. Additional information may be displayed depending upon
the application (see F30).
TARE - This key is used to establish a Tare weight as long as the following conditions are
met:
1. The indicator is not at or below Gross zero.
2. The scale is not in motion.
3. The scale is not in overload (see Appendix D for error codes).
PRINT -
This key is used to manually send weight information out to both serial ports as long
as the following conditions are met:
1. The scale is not in motion.
2. The scale is not in overload (see Appendix D for error codes).
C/CE – This key is used to exit a current function or to backspace thru a numeric entry.
F1 – This key is used as the main function key for a specification application, e.g. piece
counting or peak hold. See the F30 sub-menu for more information.
SET POINT – This key is used to enter in up to four set points thru the front panel. This key is
password protected. See Programming Set Points for more information.
UNDER – If the indicator is configured for the over/under checkweighing application (see F30
and B7), this key is used to enter in the ‘under value’ thru the front panel. This key is
password protected. See Programming Over/Under Values for more information.
OVER – If the indicator is configured for the over/under checkweighing application (see F30
and B7), this key is used to enter in the ‘over value’ thru the front panel. This key is password