RT-PRC024-EN
5
Features and Benefits
Unmatched Support
Trane Sales Representatives are a
Support Group that can assist you
with:
–
Product
–
Application
–
Service
–
Training
–
Special Applications
–
Specifications
–
Computer Programs and
much more
Standard Features
Anti-Short Cycle Timer (Standard
with ReliaTel)
Provides a 3 minute minimum “ON”
time and 3 minute “OFF” time for
compressors to enhance compressor
reliability by assuring proper oil
return.
Colored And Numbered Wiring
Save time and money tracing wires
and diagnosing the unit.
Compressors
Voyager
contains the
best compressor
technology
available to
achieve the
highest possible
performance.
Dual
compressors
are outstanding for humidity control,
light load cooling conditions and
system back-up applications. Dual
compressors are available on all
models.
Condenser Coil
Voyager boasts a patent-pending
1+1+1 condenser coil, permanently
gapped for easy cleaning.
Controls – ReliaTel
ReliaTel microprocessor controls
provide unit control for heating,
cooling and ventilating utilizing input
from sensors that measure indoor
and outdoor temperature and other
zone sensors. ReliaTel also provides
outputs for building automation
systems and expanded diagnostics.
For a complete list of ReliaTel
offerings, refer to the “Other
Benefits” section within the Features
and Benefits section of this catalog.
Conversionless Units
The dedicated design units (either
downflow or horizontal) require no
panel removal or alteration time to
convert in the field — a major cost
savings during installation.
Horizontal units come complete with
duct flanges so the contractor
doesn’t have to field fabricate them.
These duct flanges are a time and
cost saver.
Crankcase Heaters
These band or insertion heaters
provide improved compressor
reliability by warming the oil to
prevent migration during off-cycles
or low ambient conditions. These are
standard on all Voyager models.
Efficiencies
Standard or High Efficiency Cooling
available.
Easy Access Low Voltage
Terminal Board
Voyager’s Low
Voltage Terminal
Board is external
to the electrical
control cabinet. It
is extremely easy
to locate and
attach the
thermostat wire
and test operation
of all unit
functions. This is
another cost and time saving
installation feature.
Foil Faced Insulation
All panels in
the evaporator
section of the
unit have
cleanable foil-
faced
insulation. All
edges are
either captured
or sealed to
ensure no
insulation
fibers get into
the airstream.
Heat Exchanger - Drum and Tube
The cabinet features a drum and tube
heat exchanger that is manufactured
using aluminized steel with stainless
steel components for maximum
durability. The requirement for cycle
testing of heat exchangers is 10,000
cycles by ANSI Z21.47. This is the
standard required by both UL and
AGA for cycle test requirements.
Trane requires the design to be
tested to 2½ times this current
standard. The drum and tube design
has been tested and passed over
150,000 cycles, which is over 15
times the current ANSI cycling
requirements.
The negative pressure gas valve will
not allow gas flow unless the
combustion blower is operating. This
is one of our unique safety features.
The forced combustion blower
supplies pre-mixed fuel through a
single stainless steel burner screen
into a sealed drum where ignition
takes place. It is more reliable to
operate and maintain than a multiple
burner system.
The hot surface ignitor is a gas
ignition device which doubles as a
safety device utilizing a continuous
test to prove the flame. The design is
cycle tested at the factory for quality
and reliability.
He
a
t Ex
c
h
a
n
g
er
Hot Surf
ac
e I
g
n
i
tor
Ne
ga
t
i
ve Pressure G
a
s V
a
lve
For
c
ed Com
b
ust
i
on Blower
Содержание Voyager TC Series
Страница 10: ...10 RT PRC024 EN Features and Benefits Figure 1 Voyager Factory Installed Options Factory Installed Options...
Страница 84: ...84 RT PRC024 EN Figure 3 12 5 25 Tons Cooling with Optional Electric Heat Typical Wiring...
Страница 106: ......
Страница 107: ......