6
RT-PRC024-EN
Features and Benefits
Our gas/electric rooftops exceed all
California seasonal efficiency
requirements and perform even
better than the California NOx
emission requirements.
Low Ambient Cooling
All Voyager microprocessor units
have cooling capabilities down to 0°F
as standard.
Low Voltage Connections
The wiring of the low voltage
connections to the unit and the zone
sensors is as simple as 1-1, 2-2, and
3-3. This simplified system makes it
easy for the installer to wire.
Motors
All indoor fan motors are belt drive
as standard.
Pressure Cutouts
Low and high pressure cutouts are
standard on all Voyager models.
Quick-Access Panels
Remove three
or more
screws for
access to the
standardized
internal
components
and wiring.
Quick-
Adjust
Slider Plate
With the Quick-Adjust Slider Plate,
the belt and sheaves can be quickly
adjusted without moving the
mounted fan motor. The result is a
major savings in time and money.
Single Point Power
A single electrical connection powers
the unit.
Single Side Service
Single side service is standard on all
units.
Sloped Drain Pans
Every Voyager unit has a non-
corrosive, sloped drain pan made of
pre-painted steel and standard on all
units.
Standardized Components
Components are placed in the same
location on all Voyager units.
Familiarize yourself with one Voyager
and you are familiar with every
Voyager.
Due to standardized components
throughout the Voyager line,
contractors/owners can stock fewer
parts.
Through the Base Condensate
Every unit includes provisions for
through the base condensate drain
connections. This allows the drain to
be connected through the roof curb
instead of a roof penetration.
Variety of Options*
Factory Installed Options
Black Epoxy Pre-Coated Coils
The pre-coated coils are an
economical option for protection in
mildly corrosive environments.
Circuit Breaker (Required with
Through- the-Base Electrical)
This option is a factory installed
thermal magnetic, molded case,
HACR Circuit Breaker with provisions
for through the base electrical
connections. Available on all
downflow models.
Disconnect Switch (Required
with Through-the-Base Electrical)
Factory
installed 3-pole,
molded case,
disconnect
switch with
provisions for
through the
base electrical
connections are
available.
Available on all downflow models.
Codes require a method of assured
unit shutdown for servicing. Field-
installed disconnects sometimes
interfere with service access. Factory
installation of unit disconnects
reduces costs, assures proper
mounting and provides the
opportunity to upgrade to unit circuit
breaker protection.
Dehumidification (Hot
G
as
Reheat) Option
This option allows for
increased outdoor air
ventilation. It reduces
humidity levels while
increasing comfort
level in the air space.
Cooling can operate
without a demand for
dehumidification.
The hot gas reheat
coil is designed to
deliver maximum
reheat temperatures.
Hinged Access Doors
These doors
permit easy
access to the
filter, fan/
heat, and
compressor/
control
sections.
They reduce the potential roof
damage from screws or sharp access
door corners.
Motors
Factory or field installed oversized
motors available for high static
applications are available.
High Efficiency motors are also
available with efficiency ratings from
86.5 up to 91.0. It is not available for
all models.
Novar Unit Controls
Novar 3051 and 2024 are available
for Voyager Cooling and Gas/Electric
models.
Powered or Unpowered
Convenience Outlet
This option is a GFCI, 120v/15amp, 2
plug, convenience outlet, either
powered or unpowered.