15
10.WIRING DIAGRAM
1. To avoid the electrical shock, please connect the air conditioner with the ground lug. The main power plug in the air
conditioner has been joined with the ground wiring, please don't change it freely.
2. The power socket is used as the air conditioner specially.
3. Don't pull the power wiring hard.
4. When connecting the air conditioner with the ground, observe the local codes.
5. If necessary, use the power fuse or the circuit, breaker or the corresponding scale ampere.
Fig.13 AIR FILTER CLEAN
Fig.14 CONTROL WIRING FOR AC SYSTEMS
Fig.15 CONTROL WIRING FOR HP SYSTEMS
RED
GREEN
24RC
G Fan
Y1 Comp
W1/B
THERMOSTAT
INDOOR UNIT
OUTDOOR UNIT
G
R
C
Y
C
BLACK
YELLOW
BLACK
W1
W2
24C
W2
WHITE
BLACK/WHITE
RED
GREEN
W2
G Fan
Y1 Comp
W1/B
THERMOSTAT
INDOOR UNIT
OUTDOOR UNIT
G
R
C
C
B
BLACK
YELLOW
BLACK
W1
R
Y
D
24C
24RC
RED
BLUE
PURPLE
WHITE
W2
BLACK/WHITE