16

Fig.17: FAN SPEED SETTING DIAGRAM

Fig.16: FACTORY DEFAULT WIRING DIAGRAM 

HIGH VOLTAGE!

DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS

UNIT.  MULTIPLE POWER SOURCES MAY BE PRESENT.  FAILURE TO

DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

COOLING

AND FAN

ONLY SPEED

DIP SWITCH

SETTINGS

ON

123

ON

123

MEDIUM

ON

123

PROHIBITED IN THIS STATE

MEDIUM LOW

ON

123

LOW

2

ON

123

ON

123

ON

123

PROHIBITED IN THIS STATE

MEDIUM

ON

123

MEDIUM LOW

3

4

3

ON

123

ON

123

HIGH

ON

123

PROHIBITED IN THIS STATE

MEDIUM HIGH

MEDIUM HIGH

ON

123

MEDIUM

4

5

MOTOR 

TERMINAL

SETTINGS

OUTDOOR

UNIT SIZE

(TONS)

2T/3T/5T*

*Default wiring

2.5T/4T

1.5T/3.5T

 NOTES:
1. Air handler systems use the 2T/3T/5T wiring diagram as the factory default setting.
2. When the air handler system matches with a different capacity outdoor unit, refer

to the diagram to adjust the motor terminal settings and dip switch settings.

CAUTION:

NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND

ATTENTION:

NE CONVIENT PAS AUXINSTALLATIONS DE PLUS DE 150V ALA TERRE

FM

NOTES:

1: Use Copper Wire (75 Min) Only Between Disconnect Swicth And Unit .

2: To Be Wired In Accordance With NEC And Local Codes.

3: If Any Of The Original Wire ,As Supplied,Must Be Replaced.Use The Same

Or Equivalent Type Wire.

4: Connect R To R,G To G,Etc.See Outdoor Instruction For Details.

5: To Change Speed Tap,Adjust Dip Switches(SW1).

6: See Airflow Tables For Airflow Settings.

CN6

WHITE/BLACK

W2

91

NC

3N

C

CN2

71

NC

91

NC

71

NC

8N

C

PLUG LIATE

BLACK

N

W

O

R

B

E

TI

H

W

EL

P

R

U

P

E

UL

B

W

OL

L

E

Y

CN4

W2

BLACK

MEDIUM HIGH

PROHIBITED IN

THIS STATE

MEDIUM

DIP SWITCH SETTINGS

SPEED TAPS

SEE NOTE 6

RED

GREEN

WHITE

HIGH

LOW
MEDIUM

MEDIUM

LOW

MEDIUM HIGH

HIGH

YEL

BLU

Y/G

GND

GRN

BLK
RED

BRN

WHT

GRY

PINK

WHT

GRY

ORG

BRN

BLU
YEL

BLK
BLK

FM WIRE CONFIG 1

FM WIRE CONFIG 2

SEE TABLE BELOW FOR MOTOR WIRE COLORS

ETI

H

W

EL

P

R

UP

E

UL

B

W

OL

LE

Y

ETI

H

W

E

UL

B

W

OL

LE

Y

ETI

H

W

EL

P

R

UP

E

UL

B

W

OL

LE

Y

EL

P

R

UP

Содержание Oxbox J4AC4018A1

Страница 1: ...tion or operation Failure to follow these instruction may result in improper installation adjustment service or maintenance possibly resulting in fire electrical shock property damage personal injury...

Страница 2: ...orizontal left or downflow Multiple electrical entry locations Field installed electric heater kits 5 7 5 10 15 20 kW available as an accessory Dual front panel design for ease of maintenance Blower a...

Страница 3: ...e possibly resulting in fire electrical shock property damage personal injury or death The unit must be permanently grounded Failure to do so can result in electrical shock causing personal injury or...

Страница 4: ...lications Top and side power and control wiring accessible screw terminals for control wiring all combine to make the installation easy and minimize installation cost See Fig 6 2 GENERAL CAUTION Make...

Страница 5: ...as insulation so that the thickness is more than 2 in and fits inside the installation space opening Respectively condensation may form on the surface of the insulation Be sure to use insulation that...

Страница 6: ...5 8 500 21 5 8 550 18 456 UPFLOW UNIT SHOWN UNIT MAY BE INSTALLED UPFLOW DOWNFLOW HORIZONTAL RIGHT OR LEFT AIR SUPPLY Fig 6 DIMENSIONS SUPPLY AIR FLANGES ARE PROVIDED FOR FIELD INSTALLATION ELECTRICA...

Страница 7: ...ay from breaker while setting that side of breaker into opening When breaker is in place release tab locking circuit breaker into location in opening Repeat above operation for remaining breaker s if...

Страница 8: ...ont service panel removed view AIRFLOW AIRFLOW Fig 9 INDOOR COIL AND DRAIN PAN SET UP HORIZONTAL ADAPTER KIT VAPOR LINE CONNECTION LIQUID LINE CONNECTION PRIMARY DRAIN CONNECTION VERTICAL DRAIN PAN AU...

Страница 9: ...en installed in accordance with electrical codes to the unit cabinet Grounding may also be accomplished by attaching ground wire s to ground lug s provided in the unit wiring compartment Ground lug s...

Страница 10: ...W Heat Strip 24 36 60 24 36 60 24 36 60 2 7 5kW Heat Strip 3 10kW Heat Strip 4 5 15kW Heat Strip double Breaker panel 20kW Heat Strip double Breaker panel 36 60 36 60 240 208 240 208 5 29 9 26 4 30 30...

Страница 11: ...32 1 38 1 43 1 47 1 54 1 59 1 64 SCFM 1103 1073 1036 998 967 934 896 855 814 Power W 233 241 249 258 265 275 281 286 291 Current A 1 97 2 03 2 09 2 16 2 22 2 29 2 34 2 37 2 41 SCFM 898 752 603 511 405...

Страница 12: ...1284 1226 1151 1076 946 904 893 869 Power W 143 151 159 168 177 191 197 195 194 Current A 1 23 1 26 1 33 1 41 1 50 1 61 1 63 1 61 1 62 SCFM 1531 1477 1418 1366 1299 1239 1138 1064 1001 Power W 200 211...

Страница 13: ...return ductwork grills special filters accessories etc are accounted for in total resistance See airflow performance tables in this manual Design the duct system in accordance with ACCA Manual D Desig...

Страница 14: ...recommended that a professional installation technician is contacted to ensure installation of these such filtration systems are installed correctly IMPORTANT Do not double filter the return air duct...

Страница 15: ...R MANUAL BOLT 9 FILTER INSTALLATION DIMENSIONS AIR FILTER REMOVAL DIMENSIONAL DATA 1 Remove bolts manually remove air filter recover see in Fig 12 2 Hold the edge of the air filter and extract out 3 C...

Страница 16: ...the air conditioner with the ground observe the local codes 5 If necessary use the power fuse or the circuit breaker or the corresponding scale ampere Fig 13 AIR FILTER CLEAN Fig 14 CONTROL WIRING FO...

Страница 17: ...ings CAUTION NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND ATTENTION NE CONVIENT PAS AUXINSTALLATIONS DE PLUS DE 150V ALA TERRE FM NOTES 1 Use Copper Wire 75 Min Only Between Disconnect Swi...

Страница 18: ...CK FL FL BLUE BLUE 4 1 3 2 CB1 60A W1 WHITE L1 L2 L1 L2 BLUE RED LS LS ELEMENTS ELEMENTS BROWN BLACK 1 2 3 4 5 6 0 15kW HEAT KIT 10kW 5kW HEATER KIT PLUG 4 8 2 6 C 1 0 1 BLACK YELLOW 4 8 2 6 RELAY2 YE...

Страница 19: ...60A1C00A 090 factory installed This coil comes with a factory installed piston metering device See Table 1 for factory installed piston size Some system combinations will require a different sized pis...

Страница 20: ...19 13 7 70 37 32 26 21 16 10 65 38 34 29 24 19 13 60 40 36 31 27 22 17 55 41 37 34 30 26 21 Superheat F Indoor Temperature F Dry Bulb wet Bulb Outdoor Temp F Charge the system by superheat when using...

Отзывы: