background image

REMOVAL

PROCEDURE

S E R V I C E   M A N U A L

Indoor Unit

Inverter / Hybrid / 

Non-Inverter

Wall Mounted Type

4.2/5.0/6.0/7.1/8.0/9.0 kW Class
15000 Btu/h Class 

Si04-855

Содержание FTKS50FVM

Страница 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L Indoor Unit Inverter Hybrid Non Inverter Wall Mounted Type 4 2 5 0 6 0 7 1 8 0 9 0 kW Class 15000 Btu h Class Si04 855...

Страница 2: ...VLT FT60GV1G FTXS50FVMA FTKE15GV2S FTXS60FVMA FTXS71FVMA FTKE42GV1 FTXS80FVMA FTXS90FVMA FTKS50FVLT FTKS60FVLT FTXS50GVMA FTKS71FVLT FTXS60GVMA FTXS71GVMA FTKS50FVM FTXS80GVMA FTKS60FVM FTKS71FVM FTYN...

Страница 3: ...Panel 2 2 Removal of Front Grille 5 3 Removal of Horizontal Blades Vertical Blades 7 4 Removal of Electrical Box PCBs Swing Motors 9 5 Removal of Indoor Heat Exchanger 15 6 Removal of Fan Motor Fan Ro...

Страница 4: ...ON OFF button is kept pressed for 5 seconds the forced cooling operation is performed for about 15 minutes Some models have no HOME LEAVE lamp 2 Remove the air filters 1 Open the front panel to the po...

Страница 5: ...tite photocatalytic air purifying filter Some models have Air purifying filters with photocatalytic deodorizing function instead Some models have air filters only 1 Push up the bottom of the Titanium...

Страница 6: ...panel further than it stops release both the shafts and remove the front panel Slide the front panel from side to side to release each shaft When reassembling the front panel fit the right and left r...

Страница 7: ...oints 1 Remove the service cover Preparation Remove the front panel according to Removal of the Air Filters Front Panel You can remove the front grille without detaching the service cover 1 Remove the...

Страница 8: ...e The convex marks on the front panel indicate the position of the hooks 3 Pull the upper part of the front grille out and lift the lower part up and then remove the front grille Make sure that all th...

Страница 9: ...rizontal blades 2 Bend the horizontal blade slightly and release the center shaft 2 locations Remove both the horizontal blades upper and lower in the same way 3 Release the left shaft 4 Slide the hor...

Страница 10: ...l blades The unit has 3 sets of vertical blades linked to one another with interlock rods 1 Release the right and left shafts 2 Unfasten the 3 hooks for each set of vertical blades 3 Pull the vertical...

Страница 11: ...le according to the Removal of Front Grille 1 Remove the screw and remove the drip proof plate 2 Cut the clamp The locations of the clamp and the indoor heat exchanger thermistor are different dependi...

Страница 12: ...without detaching the terminal board Screw M4 30 7 Disconnect the connector for the fan motor S1 8 Disconnect the connectors for the swing motor S6 S8 S6 for horizontal blade S8 for vertical blade Som...

Страница 13: ...cal box has a hook on its back 11 Pull the electrical box out Catch the back hook of the electrical box when reassembling 2 Remove the PCBs 1 Remove the screw on the electrical box Screw M4 16 2 Push...

Страница 14: ...t the clamp 5 The signal receiver unit has 4 PCBs Unfasten the hooks and remove each PCB Disconnect every connector from each PCB Remove the signal receiver unit while pushing the hooks of connectors...

Страница 15: ...l blades S26 buzzer PCB S28 signal receiver PCB S32 indoor heat exchanger thermistor S35 INTELLIGENT EYE sensor PCB Some models have no harness for S8 Some models have no INTELLIGENT EYE sensor PCB or...

Страница 16: ...r vertical blades 1 Remove the swing shaft on the right side Remove the swing shaft 2 Remove the 2 screws and detach the swing motor assembly 3 Remove the 2 screws and remove the swing motor The assem...

Страница 17: ...efore disconnecting the refrigerant pipe If the refrigerant pipe is disconnected with the compressor operating and the stop valve open air may be sucked in and may generate an over pressure in refrige...

Страница 18: ...oor unit 1 Detach the indoor unit from the installation plate 3 Remove the indoor heat exchanger 1 Unfasten the hook of the piping fixture on the back of the indoor unit 2 Slightly widen the auxiliary...

Страница 19: ...at exchanger be sure to wear protective gloves or wrap the indoor heat exchanger with cloths You may be injured by the fins 4 Push the hooks on the right side and unfasten them 5 Pull the indoor heat...

Страница 20: ...ssembling work Step Procedure Points 1 Remove the right side plate 1 Remove the 2 screws You can remove the fan rotor without detaching the right side plate 2 Lift the right side plate and remove it 2...

Страница 21: ...t stops Then give the screw one more turn 3 Rotate the fan rotor and confirm the fan motor and the fan rotor are installed appropriately 4 Tighten the screw completely if appropriate 5 If not appropri...

Страница 22: ...Revision History Month Year Version Revised contents 06 2013 Si04 855 First edition...

Страница 23: ...ories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and acc...

Отзывы: