32
Installation
Table 4
Unit Electrical Data
Min.
Max.
Unit
Rated
Ckt.
Fuse
Compressor Motor (Each)
5
Cond. Fan Motors (Each)
Size
Voltage
6
Amp.
1
Size
2,3
Qty.
RLA
4
LRA
Qty.
FLA
Kw
200/60/3
98
125
2
39.4
269
2
4.1
0.9
230/60/3
98
125
2
39.4
251
2
4.1
0.9
CGAF
460/60/3
44
60
2
17.2
117
2
1.8
0.9
20
575/60/3
33
45
2
13.2
94
2
1.4
0.9
380/50/3
44
60
2
17.2
110
2
1.7
0.75
415/50/3
44
60
2
17.2
110
2
1.7
0.75
200/60/3
124
175
2
39.3/56.9
269/409
3
4.1
0.9
230/60/3
124
175
2
39.3/56.9
251/376
3
4.1
0.9
CGAF
460/60/3
56
80
2
17.1/25.4
117/178
3
1.8
0.9
25
575/60/3
44
60
2
13.8/20.2
95/143
3
1.4
0.9
380/50/3
55
80
2
17.3/25.2
110/174
3
1.7
0.75
415/50/3
55
80
2
17.3/25.2
110/174
3
1.7
0.75
200/60/3
146
200
2
56.9
409
4
4.1
0.9
230/60/3
146
200
2
56.9
376
4
4.1
0.9
CGAF
460/60/3
65
80
2
25.1
178
4
1.8
0.9
30
575/60/3
51
70
2
19.9
143
4
1.4
0.9
380/50/3
65
80
2
25.2
174
4
1.7
0.75
415/50/3
65
80
2
25.2
174
4
1.7
0.75
200/60/3
187
225
4
39.4
269
4
4.1
0.9
230/60/3
186
225
4
39.4
251
4
4.1
0.9
CGAF
460/60/3
82
90
4
17.2
117
4
1.8
0.9
40
575/60/3
62
70
4
13.2
95
4
1.4
0.9
380/50/3
81
90
4
17.2
110
4
1.7
0.75
415/50/3
81
90
4
17.2
110
4
1.7
0.75
200/60/3
224
250
4
35.5/55.5
269/409
6
4.1
0.9
230/60/3
223
250
4
35.5/55.5
251/376
6
4.1
0.9
CGAF
460/60/3
98
110
4
16.5/24.2
117/178
6
1.8
0.9
50
575/60/3
77
90
4
12.4/19.4
94/143
6
1.4
0.9
380/50/3
97
110
4
15.5/24.2
110/174
6
1.7
0.75
415/50/3
97
110
4
15.5/24.2
110/174
6
1.7
0.75
200/60/3
270
300
4
56.9
409
6
4.1
0.9
230/60/3
269
300
4
56.9
376
6
4.1
0.9
CGAF
460/60/3
120
125
4
25.4
178
6
1.8
0.9
60
575/60/3
95
110
4
20.2
143
6
1.4
0.9
380/50/3
119
125
4
25.2
174
6
1.7
0.75
415/50/3
119
125
4
23.2
174
6
1.7
0.75
Notes:
1. Minimum Circuit Ampacity is 125% of the largest compressor RLA plus 100% of the other compressor
RLA plus the sum of the condenser fan FLA plus any other load rated at 1 Amp or more.
2. Maximum Fuse Size is 225% of the largest RLA plus 100% of the other compressor RLA plus the sum
of the condenser fan FLA plus any other load rated at 1 Amp or more.
3. Recommended Dual Element Fuse Size is 150% of the largest compressor RLA plus 100% of the
other compressor RLA plus the sum of the condenser fan FLA plus any other load rated at 1 Amp or more.
4. RLA is rated in accordance with UL Standard 465. Local codes may take precedence.
5. All units are across-the-line starting. Compressors will never start simultaneously.
6. (60 Hz units) One field provided 115/60/1, 15 amp power supply is required to operate the evaporator
heat tape.
(50 Hz units) One field provided 240/50/1, 5 amp power supply is required to operate the evaporator
heat tape.
Содержание IntelliPak CG-SVX02B-EN
Страница 10: ...10 General Information Module Mounting Locations Screw Hole...
Страница 12: ...12 Figure 1 Typical Installation Clearances for Single Multiple or Pit Applications...
Страница 13: ...13 Figure 2 C20 Ton Unit Dimensional Data Recommended Clearances...
Страница 14: ...14 Figure 2 C25 Ton Unit Dimensional Data Recommended Clearances...
Страница 15: ...15 Figure 2 C30 Ton Unit Dimensional Data Recommended Clearances...
Страница 16: ...16 Figure 2 C40 Ton Unit Dimensional Data Recommended Clearances...
Страница 17: ...17 Figure 2 C50 Ton Unit Dimensional Data Recommended Clearances...
Страница 18: ...18 Figure 2 C60 Ton Unit Dimensional Data Recommended Clearances...
Страница 35: ...35...
Страница 36: ...36 Figure 12B Typical GBAS 0 5 Volt Connections Diagram...
Страница 37: ...37...
Страница 38: ...38...
Страница 63: ...63...
Страница 64: ......