Features and
Benefits
PKG-PRC002-EN
5
Standard Features
• 20 through 80 ton industrial/commercial
water-cooled self-contained units
• 20 through 60 ton industrial/commercial
remote air-cooled self-contained units
• Fully integrated, factory-installed, and
commissioned microelectronic controls
• Unit mounted human interface panel
with a two line x 40 character clear
language (English, Spanish, or French)
display and a 16-function keypad that
includes custom, diagnostics, and
service test mode menu keys
• Improved Trane 3-D
®
scroll compressor
• Compressor lead/lag
• CV or VAV system control
• Low ambient compressor lockout
adjustable control input
• FROSTAT
™
coil frost protection on all
units
• Daytime warmup (occupied mode) on
units with heat and morning warmup
operation on all units
• Supply air static overpressurization
protection on units with inlet guide
vanes or variable frequency drives
(VFD’s)
• Supply airflow proving
• Supply air tempering control with
heating option
• Supply air heating control on VAV with
hydronic heating option
• Emergency stop input
• Mappable sensors and setpoint sources
• Occupied/unoccupied switching
• Timed override activation
• Refrigeration circuits are completely
factory piped and tested on water-
cooled units
• Factory piped and tested, mechanically
cleanable water-cooled condensers
• Two-bolt removable condenser
waterboxes for quick and easy cleaning
• Sloped drain pans to ensure complete
condensate removal for IAQ
• Internally trapped drain connection with
cleanout
• Internally isolated centrifugal supply fan
• 14-gauge galvanized steel framework
with easily removable painted exterior
panels of 18-gauge galvanized steel
• UL listing on standard options
• Fan belts and grease lines are easily
accessible
• Access panels and clearance provided
to clean both evaporator and waterside
economizer coil fins
• Condensing pressure control on all
variable water flow systems with valves
• Programmable water purge during
unoccupied mode
• High entering air temperature limit
• Low entering air temperature limit with
waterside economizer or hydronic heat
Optional Features
• Trane communication interface module:
ICS interface control module
• Generic BAS interface
• Comparative enthalpy control
• Ventilation override from up to five
external inputs
• Remote human interface controls up to
four units
• Fully integrated, factory-installed/
commissioned variable frequency drive
control with or without optional
integrated bypass
• Fully integrated, factory-installed and
commissioned inlet guide vanes on FC
supply fan
• Waterside economizer with factory
installed piping and controls
• Waterside modulating condensing
temperature control valves include
factory installed piping and control
wiring
• Removable cast iron headers on
cleanable waterside economizer
• Flexible horizontal discharge plenum
with or without factory cut holes
• Heating options include hot water,
steam, and electric
• Refrigerant suction discharge line
service (shut-off) valves
• Protective coatings for the unit and/or
evaporator coils
• Double wall construction
• Stainless steel sloped drain pan
• Medium efficiency throwaway filters
• Through-the-door non-fused disconnect
switch
• Trane’s air quality Traq
™
damper in
airside economizer mixing box
• High duct temperature thermostat
• Dual electrical power connection
• CO
2
reset input
FC Fans With Inlet Guide Vanes
Trane’s forward-curved fans with inlet
guide vanes pre-rotate the air in the
direction of the fan wheel. This decreases
static pressure and horsepower. The
unloading characteristics of a Trane FC
fan with inlet guide vanes results in
superior part load performance.
Variable Frequency Drives (VFD)
Variable frequency drives are factory
installed, wired, and tested to provide
supply fan motor speed modulation.
VFD’s are quieter and more efficient than
inlet quide vanes and may even be
eligible for utility rebates. The VFD’s are
available with and without a manual
integrated bypass option, controlled
through the human interface (HI) panel.
Bypass control provides full nominal
airflow control to CV zone setpoints in the
unlikely event of a drive failure by
manually placing the drive in the bypass
mode.
Field Installed Accessories
• Airside economizer control with or
without mixing box
• Programmable sensors with or without
night set back for CV and VAV systems
• ICS zone sensors used with Tracer
®
system for zone control
• Field installed module kits available for
field upgrade of controls
• Ultra low leak dampers for 0-100
percent modulating fresh air
economizer
Содержание CCRC20
Страница 81: ...Dimensions and Weights PKG PRC002 EN 81 Self Contained 20 38 Tons 20 38Ton Self Contained...
Страница 82: ...Dimensions and Weights PKG PRC002 EN 82 40 80Ton Self Contained Self Contained 40 80 Ton 82...
Страница 88: ...Dimensions and Weights PKG PRC002 EN 88 Airside Economizer Airside Economizer...