Performance
Water-Cooled
Data
PKG-PRC002-EN
33
Table PD-4. SCWF/SIWF 20 Gross Cooling Capacity - 8,000 cfm, 60 gpm
Entering Water Temp
Entering Air
75 F
85 F
95 F
EDB EWB
Total
Sensible
Total
Sensible
Total
Sensible
F F
MBh
MBh
LWT
MBh
MBh
LWT
MBh
MBh
LWT
62
244
185
84.7
235
181
94.7
225
176
104.6
75
67
266
150
85.5
256
146
95.4
246
141
105.3
72
289
114
86.3
278
110
96.2
267
106
106.0
62
244
218
84.7
235
214
94.7
226
209
104.6
80
67
266
183
85.5
256
179
95.4
245
174
105.3
72
289
147
86.3
278
143
96.1
267
139
106.0
62
247
246
84.8
239
239
94.8
231
231
104.8
85
67
265
216
85.5
256
211
95.4
245
207
105.3
72
288
180
86.3
278
176
96.1
267
171
106.0
20 Ton
Note:
1. Fan curves include refrigerant coil and internal
cabinet static losses. To determine static pressure to
be used with these curves, add filter, economizer,
flexible horizontal discharge and heat pressure
drops to external duct static pressure.
Chart PD-27. SCWF/SIWF 20 Fan Performance for CV or with VFD
Chart PD-28. SCWF/SIWF 20 Fan Performance with Inlet Guide Vanes
Содержание CCRC20
Страница 81: ...Dimensions and Weights PKG PRC002 EN 81 Self Contained 20 38 Tons 20 38Ton Self Contained...
Страница 82: ...Dimensions and Weights PKG PRC002 EN 82 40 80Ton Self Contained Self Contained 40 80 Ton 82...
Страница 88: ...Dimensions and Weights PKG PRC002 EN 88 Airside Economizer Airside Economizer...