Warnings and Cautions

WARNING

R410-A Refrigerant under Higher Pressure than R-22!

The units described in this manual use R410-A refrigerant which operates at 50 to 70% 
higher pressures than R-22. Use only R-410A approved service equipment. Refrigerant 
cylinders are painted with "pink" color to indicate the type of refrigerant and may contain 
a "dip" tube to allow for charging of liquid refrigerant into the system. For specific handling 
concerns with R-410A, please contact your local sales office. 
Failure to use R-410A approved service equipment could result in standard equipment 
exploding under R-410A higher pressure which could result in death or serious injury.  

NOTICE

Use appropriate oil with R410A systems. Oil type is found at the bottom of Connection Pipe 
Requirements table (included in the outdoor unit installation manual). R-410A systems 
utilize POE (Polyolester) or PVE (Polyvinyl Ether) oil. Both oil types absorb moisture readily, 
yet, lubrication properties vary. Do not leave the sealed system open to atmosphere except 
during service for a short period of time. If the sealed system is left open longer than four 
hours, the compressor oil must be changed. These systems utilize strainers placed before 
and after the expansion device in the outdoor unit, if debris or moisture is suspected, these 
strainers must be changed. Do not break a vacuum with air. Do not leak check the sealed 
system with compressed air. Unless instructed by factory service representative, external 
refrigeration driers are prohibited. 

USE ONLY THE FACTORY RECOMMENDED OIL TYPE! 

Important! 

Environmental Concerns 

Scientific research has shown that certain man-made chemicals can affect the earth's naturally occurring 
stratospheric ozone layer when released to the atmosphere. In particular, several of the identified chemicals that 
may affect the ozone layer are refrigerants that contain chlorofluorocarbons (CFC's) and those containing hydro-
chlorofluorocarbons (HCFC's). Not all refrigerants containing these compounds have the same potential impact 
to the environment. The Company advocates the responsible handling of all refrigerants, including industry 
replacements for CFC's such as HCFC's and HFC's. 

Responsible Refrigerant Practices

The manufacturer believes that responsible refrigerant practices are important to the environment, our 
customers, and the air conditioning industry. All technicians who handle refrigerants must be certified. The 
Federal Clean Air Act (Section 608) sets forth the requirements for handling, reclaiming, recovering and recycling 
of certain refrigerants and the equipment that is used in these service procedures. In addition, some states or 
municipalities may have additional requirements that must also be adhered to for responsible management of 
refrigerants. Know the applicable laws and follow them. 

Содержание 4MXX8509B10N0

Страница 1: ...s Manual Split System R 410A Air Handler for Multi Zone Inverter System 9 000 Btu h to 24 000 Btu h Floor and Ceiling Type Models 4MXX8509B10N0 4MXX8512B10N0 4MXX8518B10N0 4MXX8524B10N0 May 2021 MS S...

Страница 2: ...Attention Warnings and Cautions appear at appropriate sections throughout this literature Read these carefully WARNING Indicates a potentially hazardous situation which if not avoided could result in...

Страница 3: ...trainers must be changed Do not break a vacuum with air Do not leak check the sealed system with compressed air Unless instructed by factory service representative external refrigeration driers are pr...

Страница 4: ...igerant Piping 18 Flaring Processing 18 Bending Pipes 18 Refrigerant Piping at the Outdoor Unit 19 Insulating the Refrigerant Piping and Connections 19 Wiring at the Indoor Unit 20 Stranded Wiring Con...

Страница 5: ...er to the installation specifications for additional requirements 5 Electrical work should be carried out in accordance with the installation manual and local state and National Electric Code NEC Insu...

Страница 6: ...electrical requirements will be met 5 Check the installation locations to ensure the weight of the units can be supported 6 Check the refrigerant pipe sizes and ensure they have been or will be instal...

Страница 7: ...ions may be included in outdoor unit 4 Flare nuts for connecting refrigerant pipes 5 Mounting fasteners 6 Wired remote control and 25 feet of connection cable typically packaged in cellophane bubble N...

Страница 8: ...nit NOTE The minimum distance from the floor to the bottom of the indoor unit is a minimum of 11 75 300mm for floor installation and 90 5 2300mm for ceiling installations Unit Main Components Wireless...

Страница 9: ...xcessive heat from soldering brazing or welding with refrigerant vapors present can form highly toxic gases and extremely corrosive acids NOTICE System Component Damage Do not remove the seal caps fro...

Страница 10: ...horizontally level 9 Be sure to leave enough space to allow access for routine maintenance clearance between the bottom of the indoor unit and the floor is a minimum of 11 75 300mm for floor installat...

Страница 11: ...rvice Procedures The maintenance and troubleshooting procedures recommended in this section of the manual could result in exposure to electrical mechanical or other potential safety hazards Always ref...

Страница 12: ...bracket by pulling it backward 6 Release the claws in the 3 places indicated 7 Release the center hook and remove the front panel 8 Release the claws in the places indicated on the electric box cover...

Страница 13: ...bolts M6 to prevent displacement of the indoor unit 6 Adjust the height so the rear side of the drain plpe is at a slight decline for improved condensate drainage 7 Reinstall and tighten the right and...

Страница 14: ...ications 2 For ceiling applications the unit must be level side to side Adjust the height of the unit fore and aft to make the drain pipe slant slightly downward so condensate water will flow properly...

Страница 15: ...25mm wall thickness 0 05 inches 1 5mm 6 The drain pipe should be as short as possible and with at least a 0 6 degree slope to avoid forming air pockets Installation of the Condensate Pipe 1 Use the s...

Страница 16: ...forming other installation processes It is recommended to apply a soap bubble solution and observe the connection 5 Evacuate each individual refrigeration circuit to 350 microns or below and close off...

Страница 17: ...will put stress on the indoor unit and could lead to leaking or breakage Install refrigeration lines matching the indoor unit refrigeration tubing diameters Tube adapters are supplied with the outdoo...

Страница 18: ...the flare part is spread evenly and there are no cracks 1 Use a refrigerant pipe bending tool to shape refrigerant piping smaller diameter piping may allow for light hand bending providing minimum di...

Страница 19: ...oor Unit Tighten the flare nut of the connection pipe at the outdoor unit valve connector Follow the flare nut guidelines in this manual Insulating the Refrigerant Piping and Connections 1 The refrige...

Страница 20: ...box of the indoor unit 3 Route the power connection cord from the back of the indoor unit and pull it toward the front through the wiring hole 4 Insert the power cord through the rubber ring 5 Pull th...

Страница 21: ...s Stranded Wire Note Match the terminal block numbers and connection wire colors with those of the indoor units WARNING 1 Ensure power supplied to the equipment both indoor and outdoor units is discon...

Страница 22: ...specification 5 Improperly installed and grounded field wiring poses fire and electrocution hazards For high voltage connections flexible electrical conduit is recommended whenever vibration transmis...

Страница 23: ...nce and must be grounded The yellow green wire of the air conditioner is the ground wire and cannot be used for other purposes or cut off otherwise it would create an electric shock hazard Do not grou...

Страница 24: ...power wiring match the unit requirements Improper wiring can create malfunction and fire or electrocution hazard 9 Are there any obstructions near the air inlets and air outlets for the indoor and ou...

Страница 25: ...Diagram NOTE The wiring diagrams in this guide are included as a reference The manufacturer has a policy of continuous product and product data improvement and reserves the right to change design and...

Страница 26: ...mensions 4MXX8509B 4MXX8524B A C Model A B H C D 4MXX8509B 34 2 870 9 2 235 26 2 665 32 812 12 5 318 4MXX8512B 4MXX8518B 4MXX8524B 47 2 1200 9 2 235 26 2 665 45 1142 12 5 318 Unit inch mm 26 Floor and...

Страница 27: ...door ambient temperature sensor is open short circuited F4 Outdoor condenser temperature sensor is open short circuited F5 Outdoor discharge temperature sensor is open short circuited C5 Jumper cap ma...

Страница 28: ...eard when unit is operating and after operating This sound occurs when the unit panels expand or contract due to temperature change The unit blows out dust When the unit has been off for a period of t...

Страница 29: ...water otherwise electric shock may occur Cleaning the Air Filter 1 Open the air inlet grille Open the two buckles on the grille as shown in Fig A below Remove the screws under the buckles with a screw...

Страница 30: ...of the heat exchanger Blow away dust by compressed air if available Never use water to wash the heat exchanger Drain Pipe Regularly check to see if the drain pipe is clogged in order to ensure drain c...

Страница 31: ...nit CONFORMSTO ULSTD 1995 CERTIFIEDTO CSASTD C22 2 N0 236 3097844 About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable energy efficient indoor...