Installation and operating manual
G1035.4 – 01/2019
EN-33
The electric overload protection (automatic circuit breaker with K-feature) must be equipped with a 30 mA safety switch (FI or RCD).
Three-phase current: 400 V (3P + N + PE), 50 Hz
Hoist control and electric connections
The hoist control and the connections must be dimensioned according to the wiring diagram.
In control systems for three-phase operation, equipment must be provided so that it shuts down the power in case of an incorrect
phase sequence to prevent a mix-up of the direction of travel UP/DOWN.
Determining the required cable cross-section:
–
In Illustration 19 determine the cable cross-section required for the code letter.
–
Determine the code letter (e.g. 'C') using Illustration 20. On hoists with two speeds the maximum rope speed is the determining
factor.
M
od
el
s
er
ie
s
M
ax
. r
op
e
sp
ee
d
one hoist
two hoists
Th
re
e-
ph
as
e
cu
rre
nt
Al
te
rn
at
in
g
cu
rre
nt
Th
re
e-
ph
as
e
cu
rre
nt
Al
te
rn
at
in
g
cu
rre
nt
m/min
400 V
230 V
400 V
230 V
X 300 P
X 400 P
9
A
C
A
E
18
A
-
B
-
X 500 P
X 520 P
L 500 P
9
A
E
B
F
18
B
-
D
-
X 600 P
X 620 P
X 820 P
9
B
D
D
F
18
C
-
E
-
X 1030 P
9
B
E
D
F
18
C
-
F
-
X 2050 P
6
C
-
F
-
12
D
-
F
-
X 2058 P
18
E
-
F
-
Illustration 19
Содержание tirak L 500 P Series
Страница 12: ...tirak EN 12 G1035 4 01 2019...
Страница 108: ...Montage und Betriebsanleitung DE 60 G1035 4 01 2019...
Страница 156: ...Manuel d installation et manutention FR 60 G1035 4 01 2019...
Страница 204: ...Montage en bedieningshandleiding NL 60 G1035 4 01 2019...
Страница 205: ......
Страница 206: ......
Страница 207: ......
Страница 208: ...G1035 4 01 2019 104060 EN DE FR NL Tractel Greifzug GmbH...