6 Appendix
6.1 Technical Data
Operating voltage: ............................................
11-27 V DC (± 5% residual ripple)
Max. current consumption
(without encoder)
: .
< 300 mA at 11 V DC, < 100 mA at 27 V DC
SSI-Encoder activation: ....................................
SSI (synchronous-serial), RS422
Clock output ...................................... TTL
Data input .......................................... Opto-coupler
Type of encoders
Rotary encoders:...............................
- without CRC, 4096/4096, binary, tree-format
- with 15 bit CRC, 28 data bits, binary
Linear encoders: ...............................
- without CRC, 24 data bits, binary
Length of cable encoder<->SSI-BOX . by length of cable adjustment max. 1000m
possible (with checksum evaluation)
SSI data interface:
Structure: ........................................... Data: 2-wire acc. to EIA RS422
Pulses: Opto-coupler input
Cable type: ........................................ Twisted-pair, well screened with wave impedance
of 100
to 130
. Min. cross section 0.25mm²
with a capacity of approx. 60 pF/m.
Screen: .............................................. Refer to chapter entitled "Connecting the Cable
Screening to the Converter Housing" on page 9
Length of cable: ................................. up to 250 m at 125 kHz, up to 50 m at 1 MHz
Transmission rate: ............................. 80 kHz - 1MHz
Transmission procedure: .................. synchronous-serial, 24 bit left-justified
Output code: ...................................... programmable (binary, Gray)
PROFIBUS-DP data interface: ..........................
RS485, PROFIBUS-DP acc. DIN 19245 part 1-3
Baud rate: .......................................... max. 12 Mbps
Station address: ................................ 3 - 99
Special features: ............................... Parameter programming according to PNO Profile
Class 2
Incremental data interface (option):
Incremental tracks: ............................ K1, /K1, K2, /K2, 1024 pulses/rev.
30 mA, short-circuit-proof
Sampling frequency: ......................... max. 250 kHz
Inputs:
P 2: ....................................... Electronic adjustment
Switching level: ................................. "0" < 8 VDC "1" > 11 VDC, max. 30 V DC
Operating temperature range: .........................
-20 to +70°C
Type of protection: ............................................
IP 67 (DIN 40 050)
Vibration .............................................................
According to DIN 40 046, Part 8
Form of vibration ...............................
sine
Frequency range ............................... 50 Hz to 2000 Hz
Acceleration ......................................
245 m/s² (25g) peak
Axes ..................................................
X-, Y- and Z-axis
Duration ............................................. 2 h/axis