![TR-Electronic SSI-BOX Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/tr-electronic/ssi-box/ssi-box_operating-manual_1146730032.webp)
Operating Manual SSI-BOX PROFIBUS-DP (PNO)
ELECTRONIC GmbH
TR - ELECTRONIC GmbH,
Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. ++49 (0)7425-228-0, Fax ++49 (0)7425-228-33
Date: 25.04.2012
TR - E - BA - GB - 0013 - 03
Page 32 of 45
3.9 Optional Incremental-Interface
The incremental information of the encoder (K1, /K1, K2, /K2) is supplied at connector
X10, passed through the driver stage and can be tapped off at connector X11. These
outputs are potential-free!
Variations (see also pin assignment in the appendix):
Option 1 (Art.-No.: 489-00004, main device)
No output of incremental tracks, interface is switched off.
Option 2 (Art.-No.: 489-00003)
With incremental tracks, TTL-Level
Option 3 (Art.-No. so far not defined)
With incremental tracks, Up = 5...24 V. Power supply for the incremental interface is
feed-in via the user itself.