![TR-Electronic SSI-BOX Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/tr-electronic/ssi-box/ssi-box_operating-manual_1146730010.webp)
Operating Manual SSI-BOX PROFIBUS-DP (PNO)
ELECTRONIC GmbH
TR - ELECTRONIC GmbH,
Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. ++49 (0)7425-228-0, Fax ++49 (0)7425-228-33
Date: 25.04.2012
TR - E - BA - GB - 0013 - 03
Page 10 of 45
1.3 Appropriate Use
The SSI-BOX exclusively is used for connection with SSI-encoders.
Usable encoder types:
Rotary encoders without checksum, 4096/4096, binary, tree-format,
exclusively usable for the nominal configuration
"Box+rotary encoder TR Gear"
Rotary encoders with checksum, 28 data bit, binary, 15 bit CRC,
usable for all nominal configurations
Linear encoders without checksum, 24 data bit, binary,
exclusively usable for the nominal configuration
"Box+rotary encoder TR Gear"
The SSI-BOX can be parameterized via the PROFIBUS according to the PNO profile
and is designed to be run on PROFIBUS-DP networks according to DIN 19245 Part 1-
3 up to a maximum of 12 Mbauds. The parameterization and equipment diagnostics
are performed by the PROFIBUS master according to Version 1.0 of the PNO encoder
profile.
In addition to the Profibus data the angular data can also output at the same time
synchronous-serial.
Note
1
2
3
4
To avoid damaging the lid seal on
the converter housing and to
guarantee sealing, you must evenly
tighten the screws crosswise.
(See the example on the left.)
Warning
Deenergize the system before carrying out wiring or opening and closing
electrical connections!
Short-circuits, voltage peaks etc. can lead to malfunctions and uncontrolled conditions
in the system or to serious personal injury or damage to property.
Before switching on the system, check all the electrical connections!
Connections that are made incorrectly can lead to system malfunctions; wrong
connections may result in serious personal injury or damage to property.
For safety reasons, mechanical or electrical changes
to the measuring systems
are prohibited!
i