Printed in the Federal Republic of Germany
TR-Electronic GmbH 2020, All Rights Reserved
06/15/2020
TR - ELE - BA - DGB - 0030 - 01
Page 81 of 88
9.2 Error count (Index 0x0020)
The parameter
Error Count
provides information on errors occurred (Events) since power-on.
Index
Subindex
Name
Length
Type
Access
0x0020
0
Error Count
16 Bit
UIntegerT
ro
9.3 Device status (Index 0x0024)
The parameter
Device Status
contains the current device status and can be read by any PLC
program or corresponding IO-Link tools.
In
case
of
an
error
by
means
of
the
parameter
Detailed device status
(Index 0x0025) the cause of the error is indicated in detail.
Index
Subindex
Name
Length
Type
Access
0x0024
0
Device Status
8 Bit
UIntegerT
ro
Parameter value
Description
0x00
No failure,
device is operating properly
0x01
Maintenance / intervention required
0x02
Out-of-Specification
0x03
Not supported
0x04
Failure
0x05...0xFF
Reserved