Parameterization
TR-Electronic GmbH 2020, All Rights Reserved
Printed in the Federal Republic of Germany
Page 68 of 88
TR - ELE - BA - DGB - 0030 - 01
06/15/2020
Index 0x004B: Measurement Update Period
7.3.5
The parameter
Measurement Update Period
defines the time for calculating the measuring value.
Index
Subindex
Name
Length
Type
Access
0x004B
0
Measurement
Update Period
8 Bit
UIntegerT
rw
Value
Assignment
Default
0x00
1 ms
X
0x01
2 ms
0x02
3 ms
0x03
4 ms
0x04
5 ms
0x05
6 ms
0x06
7 ms
0x07
8 ms
0x08
9 ms
0x09
10 ms
0x0A
15 ms
0x0B
20 ms
0x0C
25 ms
0x0D
30 ms
0x0E
50 ms
0x0F
100 ms
0x10
200 ms
0x11
500 ms
Index 0x004C: Position Hysteresis
7.3.6
Caused by the scanning unit, unwanted edge jitter on the lowest-order bit (LSB bit) can occur. To
prevent this, a hysteresis of one step can be added.
Index
Subindex
Name
Length
Type
Access
0x004C
0
Position Hysteresis
8 Bit
UIntegerT
rw
Value
Assignment
Description
Default
0x00
Inactive
without hysteresis
X
0x01
Active
with hysteresis