Parameterization
TR-Electronic GmbH 2020, All Rights Reserved
Printed in the Federal Republic of Germany
Page 72 of 88
TR - ELE - BA - DGB - 0030 - 01
06/15/2020
7.6 External Output
– Parameter (optional)
Index 0x0064: Ext. Output Function
7.6.1
The parameter
Ext. Output Function
defines the function for the external switching output.
Definition of the errors se
e “Process Input Data - Error Status” on page 60.
Index
Subindex
Name
Length
Type
Access
0x0064
0
Ext. Output Function
8 Bit
UIntegerT
rw
Value
Assignment
Description
Default
0x00
Disabled
Function switched off
X
0x01
Temperature
Temperature range exceeded
0x02
Intensity
Intensity value below
0x03
Hardware Failure
Hardware error
0x04
Every Failure
Combined error message
0x05
Speed-Check
Position error
0x06
Measurement Plausibility
Function switched off
Index 0x0065: Ext. Output Level
7.6.2
The parameter
Ext. Output Level
defines the output level of the external switching output.
Index
Subindex
Name
Length
Type
Access
0x0065
0
Ext. Output Level
8 Bit
UIntegerT
rw
Value
Assignment
Description
Default
0x00
Low Active
When the event is active,
switching output = “0”
0x01
High Active
When the event is active,
switching output = “1”
X