Parameterization
TR-Electronic GmbH 2008, All Rights Reserved
Printed in the Federal Republic of Germany
Page 122 of 155
TR - ECE - BA - DGB - 0073 - 07
06/27/2017
7.6.3.3 Attribute 0x0C, Direction Counting Toggle
Direction Counting Toggle
sets the counting direction of the measuring
system:
BOOL
Access Value Description
Default
Set/Get
= 0 Position increasing clockwise (view onto the shaft)
X
= 1 Position decreasing clockwise (view onto the shaft)
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01
0x30
0x0C
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #12
So that this attribute is accepted and saved permanently,
0x70 Accept
Parameter
must be performed.
7.6.3.4 Attribute 0x64, Position Value
Position Value
returns the current position of the measuring system as binary
coded value:
ULINT, read only
Position value
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
CEx-65
2
7
- 2
0
2
15
- 2
8
2
23
- 2
16
2
31
- 2
24
-
-
-
-
COx-65
2
7
- 2
0
2
15
- 2
8
2
23
- 2
16
2
31
- 2
24
2
39
- 2
32
2
47
- 2
40
2
55
- 2
48
2
63
- 2
56
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01
0x30
0x64
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #100