Trouble-shooting and diagnostic facilities
©
TR-Electronic GmbH 1997, All Rights Reserved
Printed in the Federal Republic of Germany
Page 42 of 45
TR - ECE - BA - GB - 0009 - 08
03/04/2010
4.2.2.7 Supported alarms
Bit
Meaning
= 0
= 1
Bit 0
Position error
Not supported
Supported
Bit 1
Supply voltage monitoring
Not supported
Supported
Bit 2
Current
consumption
monitoring
Not supported
Supported
Bit 3
Diagnostic routine
Not supported
Supported
Bit 4
Memory error
Not supported
Supported
Bit 5-15 Not applicable
4.2.2.8 Warnings
Bit
Meaning
= 0
= 1
Bit 0
Frequency exceeded
No
Yes
Bit 1
Permissible temp. exceeded
No
Yes
Bit 2
Control reserve light
Not reached
Reached
Bit 3
CPU watchdog status
OK
Reset performed
Bit 4
Operating time warning
No
Yes
Bit 5-15 Battery charge
OK
Too low
4.2.2.9 Supported warnings
Bit
Meaning
= 0
= 1
Bit 0
Frequency exceeded
Not supported
Supported
Bit 1
Permissible temp. exceeded
Not supported
Supported
Bit 2
Control reserve light
Not supported
Supported
Bit 3
CPU watchdog status
Not supported
Supported
Bit 4
Operating time warning
Not supported
Supported
Bit 5-15 Reserved
4.2.2.10 Profile version
Diagnostic bytes 24-25 indicate the version of the PNO encoder profile supported by
the encoder. They consist of the revision number and revision index (e.g. 1.40
corresponds to 0000 0001 0100 0000 or 0140 (hexadecimal code) )
Byte 24
Revision number
Byte 25
Revision index