Device description / start-up
©
TR-Electronic GmbH 1997, All Rights Reserved
Printed in the Federal Republic of Germany
Page 20 of 45
TR - ECE - BA - GB - 0009 - 08
03/04/2010
3.8.1.5 TR-mode position, identifier F1 (HEX):
The encoder uses two input words and two output words which are consistently
transferred via the bus.
Double input word ID x
Data byte 3
Data byte 2
Data byte 1
Data byte 0
LSB
MSB
Input byte x+0
Input byte x+1
Input byte x+2
Input byte x+3
Double output word for preset adjustment OD x
Data byte 3
Data byte 2
Data byte 1
Data byte 0
LSB
MSB
Output byte x+0
Output byte x+1
Output byte x+2
Output byte x+3
P
Relevant parameter data:
•
Count
direction
•
Commissioning diagnostic control (on/off)
•
Total measuring range
•
Revolutions
numerator
•
Revolutions
denominator
•
•
Code PROFIBUS interface
•
Preset 1 value (24V inputs)
•
Preset 2 value (24V inputs)
New in version 4.x
•
Teach-In function (commissioning function)
•
Short diagnostic
•
Limit switch lower limit
•
Limit switch upper limit
1
SSI on request, not standard