2.4 Connecting the Cable Screening to the Bus-Cap
To prevent disturbance signals entering the encoder housing, we used cable screw
glands with which it is possible to connect the screen on the inside. For this reason,
no
connection point for the screen is provided inside the cup-cap.
Procedure:
1. Screw the cable screw gland into the housing.
2. Dismount the compression nut (1) and the terminal holder (2).
3. Push the compression nut (1) and the terminal holder (2) over the cable.
4. Strip the cable; push back the braiding around the terminal holder (2) such that the
braiding goes over the inner O-ring (3) and does not lie over the cylindrical section
or the torsional bars.
5. Insert the terminal holder (2) into the intermediate gland (4) such that the torsional
bars fit into the intended lengthwise grooves in the intermediate gland (4).
6. Screw the compression nut (1) to the intermediate gland (4).
Part 1
Compression nut
Part 2
Terminal holder
Part 3
Inner O-ring
Part 4
Intermediate gland