4.2.2.2 Operating status
Bit
Meaning
= 0
= 1
Bit 0
Code sequence
Increasing
clockwise
Increasing
counter-
clockwise
Bit 1
Class-2 functions
No, not
supported
Yes
Bit 2
Diagnosis
No, not
supported
Yes
Bit 3
Status scaling function
No, not
supported
Yes
Bit 4
Not applicable
Bit 5
Not applicable
Bit 6
Not applicable
Bit 7
Not applicable
4.2.2.3 Encoder type
Code Meaning
00
Single-turn absolute encoder (rotary)
01
Multi-turn absolute encoder (rotary)
See encoder profile for other codes
4.2.2.4 Single-turn resolution
The hardware single-turn resolution of the encoder can be read out via bytes 11-14.
4.2.2.5 Number of resolvable revolutions
The maximum number of encoder revolutions can be read out via diagnostic bytes 15-
16.
4.2.2.6 Additional alarms
Byte 17 is reserved for additional alarms, although no other alarms are implemented.
Bit
Meaning
= 0
= 1
Bit 0-7
Reserved