5056.42562
54 5/16"
44 1/2"
3 5/8"
63 7/8"
34 13/16"
48 1/8"
44 1/2"
62 9/16"
35 5/8"
34 1/8"
Figure 1: TC54 Dimensions.
Figure 2: TC54 Mantle clearances.
Figure 3: Mantel clearances.
* MANTEL CLEARANCE
A
17”
B
15”
C
12”
** MANTEL DEPTH
D
12”
E
6”
F
1”
MANTEL CLEARANCE
CHART
NOTE:
To ensure that the
hearth does not
interfere with the
window frame, the
fireplace must be
raised.
Refer to
‘Hearth Extension’
section for details.
Minimum Clearances:
Side standoffs .................................0 in. ..................(0 mm)
Back standoffs ................................0 in. ...................(0 mm)
Top standoffs ...................................0 in. ...................(0 mm)
Bottom of appliance ........................0 in. ...................(0 mm)
Adjacent side wall ...........................4 in. ...............(102 mm)
Ceiling to appliance .........................24 in. .............(610 mm)
*Mantel to appliance ........................See Fig.#2
**Maximum Mantel extension ..........See Fig.#2
Mantel support ................................4 in. ...............(102 mm)
Vertical vent pipe ............................1 3/4" in. .........(45 mm)
Horizontal Vent pipe
(Top, sides and bottom) ...................1 3/4" in. .........(45 mm)
24”
4”
MANTEL
ADJACENT WALL
OR MANTEL
SUPPORT
CEILING
A 18" DEEP, 2" THICK, NON-COMBUSTIBLE HEARTH MUST
BE PLACED IN FRONT OF THE FULL WIDTH OF THE GLASS
*
**
MAY USE COMBUSTIBLE
FACING MATERIAL IN THIS AREA
NON-COMBUSTIBLE
FINISH MATERIAL
SEE FIG #11 & 12
NON-COMBUSTIBLE ZONE.
DO NOT INSTALL ANY COMBUSTIBLE
MATERIAL, ELECTRICAL WIRING OR GAS
PLUMBING IN THIS AREA.
COMBUSTIBLE FRAMING
AND FINISH WALL ABOVE
STANDOFFS
STANDOFFS
STEEL FRAMING
FIREPLACE FRONT
TOP OF LINTEL BAR
A
B
C
D
E
F
43 5/8”
5
TC54D _111215-44
Fireplace Dimensions
Minimum Clearances to Combustible Material