5056.42562
CAUTION:
Turn off gas and electrical power supply (if applicable) and allow ample time for unit to cool before servicing appliance. It is
recommended that the fireplace and its venting should be inspected at least once a year by a qualified service person.
Glass Panel:
Warning: Do not operate fireplace with glass panel removed, cracked or broken. Replacement of the glass panel should be
done by a licensed or qualified service person.
Do not strike or otherwise impact the glass in anyway that may cause it to break. If the glass becomes cracked or broken
it must be replaced before using the fireplace. Replacement glass can be obtained from your nearest Town & Country
Fireplaces
TM
dealer. The size required is 52" x 42" x 5mm. Use ceramic glass only. Do not substitute with any other type.
To remove broken glass, remove window frame as noted in "Window Frame Removal" section.
Unclip the Glass Retainer Clips located at the top and sides of the Window Frame. Pull the top edge of the glass out of
the frame first, then lift it up and out of the bottom edge.
Install the new piece of glass with the gasket into the frame so that the thicker bead of gasket faces the fireplace.
Re-install glass retaining clips.
Annual Inspection:
a) Remove glass panel and inspect the decorative burner media (such as logs, pebbles, glass etc) for soot build up. If
excessive build up of soot is present, have a qualified service person inspect and adjust the unit for proper combus-
tion. Clean the decorative media and use a brush or vacuum cleaner to clean the burner, paying close attention to the
burner ports.
b) Check the pilot system for proper flame size and operation. Clean pilot free of soot, dust or any other deposits
(Figure 69).
c) Check that the vent pipe and vent terminal are open and free from blockage or debris. If the venting is disassembled
for cleaning, it must be properly assembled and re-sealed. Refer to VENTING section for proper procedure.
d) Check glass panel gasket, replace if necessary. It is important that the glass seal be maintained in good condition.
e) Check and replace batteries as needed.
Note:
The appliance area must be kept clear and free from combustible materials, gasoline and other flammable vapours
and liquids.
Periodically:
a) Viewing glass may be cleaned as necessary with fireplace glass cleaner.
b) Exterior finish may be cleaned with mild soap and water.
CAUTION:
Do not use abrasive cleaners on glass or any other part of the fireplace.
Do not clean glass when hot.
Figure 69: Pilot
assembly.
38
TC54D _111215-44
Maintenance
Содержание TC54D
Страница 41: ...5056 42562 Wiring Diagram 41 TC54D _111215 44 ...
Страница 43: ...5056 42562 43 TC54D _111215 44 ...