5056.42562
Figure 29: Complete communication
wiring.
TO HOME
AUTOMATION
SYSTEM
NOTE:
•
Digital I/O must be connected to a dry contact relay.
•
Analog flame and light input through 0 - 10 volt DC signal
scaled as follows:
Low = 1 volt
High = 10 volts
NOTE:
When a signal has been supplied by the home automation system,
the fireplace control will repeat the signal every 2 hours or until a
new command has been received.
The home automation feature supplied with this fireplace is capable
of controlling the flame and light on/off function with the use of a dry
contact relay common to home automation systems. Furthermore, the
flame and light level may be modulated from high to low using the
0 - 10 volt analog output available on most home automation
systems.
(Figure 30) shows the wire designations required to connect the fire-
place to a home automation system.
Home Automation
TO FIREPLACE
Note: Leave the wall switch on the “Remote” setting when
using home automation.
Figure 30: Home automation wiring diagram.
17
TC54D _111215-44