5056.42562
Hearth Extension
Caution:
A minimum 2” thick non-combustible hearth extension extending 18” in front of this fireplace
must be fitted if a combustible sub floor extends in front of the fireplace. To ensure that the
hearth does not interfere with the safety screen, the fireplace must be raised to ensure that the
hearth extension is no more than 1” above the bottom of the fireplace.
The fireplace can be raised using combustible or non-combustible materials ensuring that it
is fully supported along the full width and depth of the fireplace.
Hearth extension
2” thick minimum
18” wide minimum
Width of glass
Bottom of fireplace
1” max above bottom of fireplace
Lintel
Figure 21: TC54D Hearth extension.
Max 4 1/2
14
TC54D _111215-44
Figure 20: Framing edge location.
This fireplace may be recessed up
to a maximum depth of 4½” from
the screen, this recess must be
constructed from non-combustible
material. The space between the
outside lintels and the firebox must
be completely free of any debris
and the window with trim fitted must
be able to move freely. No building
material is permitted to protrude
past the lintel bars attached to the
fireplace under ANY circumstance.
NON-COMBUSTIBLE
FINISH MATERIAL
NON COMBUSTIBLE
BUILDING MATERIAL
MAY NOT EXTEND PAST
THIS POINT
AREA INSIDE LINTEL
MUST REMAIN FREE OF
OBSTRUCTIONS
Содержание TC54D