Note: Installation must be performed by a qualified installer, service agency or gas supplier.
Figure 28: Junction box wiring.
Firebox access panel
Figure 27: Firebox access panel.
The gas control system is located on the right hand side of the firebox behind an access panel and the decorative firebox
panel (if installed). The fireplace is operated via a wall control and a hand held remote control unit.
The wall control is connected to the fireplace by a 40 ft. communication cable
supplied with the fireplace.
Installation
1. Place the fireplace in the desired location.
2. Remove the glass door from the fireplace.
3. Remove access panel from bottom left hand side of the firebox (Figure 27).
4. Ensure that the switch on the IFC board is set to PV (Power Vent)
(Figure 29).
5. Connect 110 V. AC electrical supply to the wires installed inside the
junction box (Figure 27). The fireplace is rated at 110 volts, 60Hz, 0.25A.
The optional power vent kit is rated at 115 volts, 60Hz, 1.8A. The electrical
wires can be accessed from both inside and outside the junction box by
removing one of the two small access panels (Figure 28 and Figure 29).
6. Attach the wall switch to the framing in the desired location. (40 ft is
supplied with fireplace).
7. Route the wall switch control cable as required to the wall switch (Figure
31).
8. Attach one end of the wall switch control cable
to the interface board (Figure 29), and the other
end to the wall control (Figure 31).
9. Do not install batteries into the wall switch
(Figure 32). Battery holder must remain
empty.
10. If not already installed, install the burner using
the instructions supplied with the burner kit.
11. Turn on the gas supply and check that all
connections are tight and leak free.
12. Turn on gas and electrical supplies.
13. Move the center button on the wall control
(Figure 30) to the “ON” position. The igniter
will start to spark. After a short delay, the
pilot will light followed by the main burner.
JUNCTION BOX
Electrical
This entire length of the supplied cable MUST be used. DO NOT substitute
this cable with any other cable. Do not add on to the length of this cable. Wall
switch for the fireplace must be located in the same room as the fireplace.
Transformer
Vacuum
switch
Inside access
panel
Gas
connector
Wall switch
connector
Junction box
Module
Interface board
Power vent
switch
Regulator
board
Gas valve
Figure 29: Valve assembly components.