User Manual for Machine Vision Cameras
113
11.10
IUX series camera’s I/ O electrical properties
11.10.1
IUX series camera’s opto
-
isolated input circuit (line0)
In the camera I/O control, opto
-
isolated input circuit is shown in Figure 11
Figure 11
-
42
Opto
-
isolated input circuit
Logic 0 input level: 0~2.2VDC (OPTO_IN pin)
Logic 1 input level: 3.3~24VDC (OPTO_IN pin)
Maximum input current: 30mA
The input level is between 2.2V and 3.2V, the circuit action state is uncertain, please avoid the input voltage working
in this range.
Figure 11
-
43
Input logic level
Input rise delay (TDR): 6us
Input drop delay (TDF): 6us
11.10.2
IUX series camera’s opto
-
isolated output circuit(line1)
In camera I/O control, opto
-
isolated output circuit is shown in Figure 11
Figure 11
-
44
Opto
-
isolated output circuit