5-11
13. VARIOUS DISPLAY MODES
In this system, various LED display patterns are provided
in relation to the display modes shown in Table 5-7. Op-
erations from AC on to power on and power off will be
given below.
Data of the non-volatile memory are checked at the AC on,
and all the LED are turned on in red in the initial use. In
second or later use, all the LEDs are turned on in green and
the unit enters the standby status.
In the standby status, only the STANDBY/ON LED is
turned on in orange, and the main power is off and the lamp
power is also off.
When the power is on by pressing the STANDBY/ON key,
the unit enters a normal status in passing through follow-
ing processes.
1.
The main power is on, and STANDBY/ON LED turns
on in green.
2.
The lamp power is on, and LAMP LED blinks in green
for about 3s.
3.
With the lamp turned on, LAMP LED turns on in
green and the unit enters the normal status.
4.
If the lamp does not turn on, STANDBY/ON LED
turns on in orange, and the LAMP LED blinks for
about 1 min. and then the unit returns to the standby
status.
In the normal status, STANDBY/ON LED and the LAMP
LED are turned on in green, and the main power and the
lamp power are turned on.
When the power is turned off by pressing the STANDBY/
ON key, the unit enters the standby status in passing through
following processes.
1.
When the lamp power is turned off, STANDBY/ON
LED turns on in orange.
2.
The LAMP LED blinks in green for about 1 min. For
this period the lamp can not be turned on again by the
STANDBY/ON key.
3.
When blinking of the LAMP LED stops, only the
STANDBY/ON LED turns on in orange. After this
the lamp can be turned on again by the STANDBY/
ON key.
4.
Moreover, the fan works for about 2 min. to lower
temperature of the unit. For this period the main
power is kept turning on.
5.
When the main power turns off, the fan also stops
and returns to the standby status.
If an error occurs due to some causes, the STANDBY/ON
LED turns on in red, and the error information is kept in
the display status of the LAMP and TEMP LEDs. When
the error is detected, the unit enters the standby status after
cooling down process for about 2 min. In this case, if the
error status continues, the error display is also kept and
any key entry is not accepted.
For the error due to the over time of the lamp-on time, the
error is not released until the internal timer is reset (boot-
ing the system by turning the AC on with [–], [+], and [IN-
PUT] keys pressed at the same time) after replacement of
the lamp.
Table 5-7 Table of various display modes
ON
LAMP
TEMP
Contents
Status
Remedy
X
X
X
Standby power abnormal
at AC on
Repair
Green
Green
Green
Non-volatile memory OK
at AC on
Normal
Red
Red
Red
Non-volatile memory NG
at AC on
Initialization
Orange
X
X
Standby
at off
Normal
Green
X
X
Lamp on
at on
Normal
Green
(Green)
X
Lamp heat up
at on
Normal
Green
Green
X
Lamp on
during on
Normal
Green
X
X
Lamp off
at off
Normal
Orange
(Green)
X
Lamp cooling down
at off
Normal
Red
X
X
Main power abnormal
at/during on
Repair
Red
Red
X
Lamp not turns on
at/during on
Repair or preparation failure
Red
Orange
X
Lamp life terminated
at on
Works after about 2500H
Red
X
(Red)
Air suction fan stop
at on
Repair
Red
X
(Orange)
Exhaust fan stop
at on
Repair
Red
X
(Green)
Fan filter open
always
Close
Red
X
Red
Temperature sensor 1 abnormal
always
Lowers temperature inside unit
X
stands for off, ( ) stands for blinking.
Содержание TLP411E
Страница 1: ...FIE NO 336 9612 Dec 1996 TECHNICAL TRAINING MANUAL 3 LCD DATA PROJECTOR TLP411U TLP411E ...
Страница 4: ...1 1 SECTION I MAIN POWER SUPPLY CIRCUIT ...
Страница 10: ...2 1 SECTION II LAMP HIGH VOLTAGE POWER SUPPLY CIRCUIT ...
Страница 12: ...3 1 SECTION III OPTICAL SYSTEM ...
Страница 16: ...4 1 SECTION IV RGB DRIVE CIRCUIT ...
Страница 25: ...5 1 SECTION V MICROCOMPUTER ...
Страница 39: ...6 1 SECTION VI DIGITAL CIRCUIT ...
Страница 63: ...7 1 SECTION VII VIDEO SIGNAL PROCESS CIRCUIT ...
Страница 77: ...8 1 SECTION VIII CCD CAMERA CIRCUIT ...
Страница 80: ...9 1 SECTION IX FLUORESCENT LAMP INVERTER CIRCUIT ...
Страница 83: ...9 4 3 CIRCUIT DIAGRAM Fig 9 5 Cicuit diagram ...
Страница 84: ...TOSHIBA AMERICA CONSUMER PRODUCTS INC NATIONAL SERVICE DIVISION 1420 B TOSHIBA DRIVE LEBANON TENNESSEE 37087 ...