Toshiba
11-1-2. Fixing Frame Assembly
1) Detach the two air filters.
2) Disconnect the plasma ion charger connector
and the earth lead (black). (The earth lead is
connected to the heat exchanger with a screw.)
3) Remove the two screws securing the fixing
frame to the rear of the indoor unit.
4) While turning the upper part of the fixing frame
to the front, release the front claw of the fixing
frame from the rear of the indoor unit.
11-1-3. Electric Parts Cover
Detached
1) Perform all the steps in
11-1-1.Removing the
Front Panel and Moving Panel
.
2) Remove the screw beside the screw that
secures the electric parts box assembly.
3) Remove the connector cover screws and
detach the connector cover.
4) While pressing the claw of the lead wire cover
in the direction shown in the figure, lift the
bottom of the lead wire cover to detach it.
5) Disconnect the connectors below.
• Louver motor connector (24P) for louver
• Fan motor connector (5P)
• Louver motor connector (5P) for movable
panel
• Minus ion charger connector (4P)
6) Remove the motor base assembly by releasing
the claw.
7) Remove the earth screw, TC sensor, and TCj
sensor.
CAUTION
When attaching the electric parts assembly
• Insert the projection at the rear of the indoor unit into
the upper hole in the electric parts assembly.
• Check that the fan motor lead wires are connected as
shown in the figure.
When attaching the motor base assembly
• Before attaching the motor base assembly, connect
the earth wire and install the TC and TCj sensors.
• Insert the bottom of the motor base assembly into the
portion shown in the figure.
• Insert the motor cover projection into the hole in the
right side panel of the motor base assembly.
Fixing frame
Air filter
Screws
Earth screw
(Plasma ion charger)
Connector
(Plasma ion charger)
Claws
(Upper part)
Claws
(Front part)
+00A08-010_01EN_SVM_HighWallHeatPump.book Page 95 Wednesday, March 4, 2009 11:22 AM