High Wall, Heat Pump Type
Service Manual
94
Toshiba
11
REPLACING THE MAIN PARTS
11-1.Indoor Unit
11-1-1. Removing the Front
Panel and Moving Panel
1) Open the moving panel, and support the
moving panel by the panel support on the right
side.
2) Remove the four set screws on the front panel.
3) Insert your thumb into the air outlet bottom
section, and lift up the front panel bottom.
4) Close the moving panel to remove the clips on
the top side as shown below.
Press your finger down on the clip on the front
panel top, and lift up the panel back edge so
that the clip is released (5 locations).
WARNING
Since high voltages is applied to electrical parts, turn off the power without fail before
starting replacement work.
After repairs have been completed and the front panel and cabinet have been attached,
perform test run and check for smoke, unusual sound, and other abnormalities.
Failure to do so may cause fire or electric shock. Make sure that the cabinet is attached before
starting test run.
Perform the following when repairing the refrigeration cycle.
• Watch out for fire in the surrounding area. If a gas stove or other appliance is being used,
extinguish the flames before starting work. If the flames are not extinguished, they may ignite
oil mixed with the refrigerant gas and may cause fire or burn injury.
• Do not use welding equipment in an airtight room.
Carbon monoxide poisoning may be caused if the room is not well ventilated.
• Do not use welding equipment near flammable materials.
Flames from the equipment may cause the flammable materials to catch fire and may result
in fire or burn injury.
CHECK
WATCH OUT FOR FIRE
CAUTION
Wear thick gloves such as cotton work gloves during repair work. Failure to do so may
cause injury by parts.
WEAR GLOVES
Moving panel
Panel support
Front panel
Clip
Clip
Clip
Clip
Clip
+00A08-010_01EN_SVM_HighWallHeatPump.book Page 94 Wednesday, March 4, 2009 11:22 AM