High Wall, Heat Pump Type
Service Manual
103
Toshiba
Precautions when attaching the inverter box
View from behind
11-3-4. Outdoor Unit Control
P.C. Board
1) Disconnect the leads and connectors
connected between the control P.C. board
assembly and other parts.
NOTE
When leads are clamped with cable ties, cut the cable
ties.
Leads connected to terminal: Disconnect the 3P
connector (black/white/orange).
Leads connected to compressor: Disconnect the 3P
connector.
Leads connected to reactor: Disconnect the two 2P
connectors.
Earth lead (black): Remove the screw.
Insert the heat insulator into
the gap of the partition board.
Partition board
Insert the bent portion at
the lower part of the
inverter box into the gap
of the partition board.
Link up the slit of
the partition board
with the boss of the
inverter box.
Hook the
inverter fixing
plate to the
partition board.
+00A08-010_01EN_SVM_HighWallHeatPump.book Page 103 Wednesday, March 4, 2009 11:22 AM