High Wall, Heat Pump Type
Service Manual
42
Toshiba
Louver position in dry operation
8-9-2. Air Direction Adjustment
• The louver position can be arbitrarily set up by
pushing [FIX] button.
8-9-3. Swing
1) When pushing [SWING] button during
operation, the louver starts swinging.
2) Each time you press the SWING button, you
can change the swing mode.
(Vertical swing
→
Horizontal swing
→
Vertical
and Horizontal swing
→
Stop swinging)
• Swing operation is performed in width 35° with the
stop position as the centre.
• If the stop position exceeds either upper or lower
limit position, swing operation is performed in width
35° from the limit which the stop position exceeded.
8-10.SLEEP MODE
Operation
8-10-1. Cooling Operation
When pushing [SLEEP MODE] button on the remote
controller, a quiet and mild operation is performed by
reducing the fan speed and the compressor speed.
This function operates the air conditioner with the
difference between the set and the room temperature
as shown in the above figure.
The time correction is performed for 8 minutes each.
1) The indoor fan speed is controlled between W6
and W3.
The compressor speed in control as shown in
the above figure.
2) The set temperature increased 0.5°C per hour
up to 2°C starting from the set temperature
when SLEEP MODE has been received.
Dry operation
Initial setting of “Cooling storage position”
Louver : Directs downward (23°)*1
Horizontal
blowing
Inclined
blowing
Inclined
blowing
blowing
downward
Inclined
blowing
Inclined
blowing
12
11
10
9
8
7
6
5
4
3
2
1
Zone
07
PKVP
35
30
25
20
15
10
10
0 OFF
1H
2H
3H
4H
time
Time
correction
Fan speed
Compressor speed (rps)
10
PKVP
35
30
25
20
15
10
10
OFF
13
PKVP
41
35
29
23
17
11
10
OFF
16
PKVP
45
38
32
25
18
12
10
OFF
18
PKVP
50
42
35
27
20
12
10
OFF
W6
W5
W4
W3
+ 1
zone
± 0
–1
zone
(min 1)
TA-Tsc
[°C]
+4.0
+3.5
+3.0
+2.5
+2.0
+1.5
+1.0
+0.5
0.0
–1.0
+6.5
+6.0
+5.5
+5.0
+4.5
–0.5
–1.5
–2.0
+00A08-010_01EN_SVM_HighWallHeatPump.book Page 42 Wednesday, March 4, 2009 11:22 AM