– 2
2
–
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
L = 10mH, 16A
2
Outdoor fan motor
3
Suction temp. sensor (TS sensor)
10k
Ω
(25°C)
4
Discharge temp. sensor (TD sensor)
62k
Ω
(20°C)
5
Outside air temp. sensor (TO sensor)
10k
Ω
(25°C)
6
Heat exchanger temp. sensor (TE sensor)
10k
Ω
(25°C)
7
Terminal block (5P)
30A, AC600V
RAS-09
E
A
Series
RAS-12
E
A
Series
9
COIL FOR P.M.V.
DC12V
10
Coil for 4-way valve
CAM-MD 12TCTH-4
STF-01U8Z
Compressor
(Inverter attached)
(Inverter attached)
(Inverter attached)
8
(Inverter attached)
DA89X1C-23FZ2
DA111A1F-20F2
CH-57-Z-T
ICF-340UA40-2 DC340V, 40W
11 Pressure SW.
ACB-4UB82W
4.7 MPa
RAS-09
E
K
Series
(for indoor)
RAS-12
E
K
Series
2 Room temp. sensor (TA-sensor)
10k
Ω
at 25°C
3
Heat exchanger temp. sensor (TC-sensor)
10k
Ω
at 25°C
4 Louver motor
Output (Rated) 1W, 16 poles, DC12V
(
−
)
(
−
)
24BYJ48-HTP
RPG-240-25A AC240V, 25W
1
ICF-340U30-2 AC220V, 30W
No.
Fan motor
Parts name
Specifications
Type
No. Parts name Model name Rating
Reactor
1
3-phases 4-poles 750W
3-phases 4-poles 680W
FILE NO. SVM-13069
6-2. Outdoor Unit
Содержание RAS-09EAV-UL
Страница 18: ...5 WIRING DIAGRAM 5 1 RAS 09EKV UL RAS 09EAV UL FILE NO SVM 13069 18 ...
Страница 19: ... 19 FILE NO SVM 13069 5 2 RAS 09EKV UL RAS 09EAV2 UL ...
Страница 20: ...5 3 RAS 12EKV UL RAS 12EAV UL FILE NO SVM 13069 20 ...
Страница 21: ...FILE NO SVM 13069 5 4 RAS 12EKV UL RAS 12EAV2 UL 21 ...
Страница 164: ...TOSHIBA CARRIER THAILAND CO LTD ENGINEERING DATA BOOK 1 1 Inverter Single Split RAS 09 22EKV UL RAS 09 22EAV2 UL ...