– 13 –
11-2. How to Judge Faulty Parts by Symptoms
One of the most important matters for the repair of air conditioners is accurate trouble analysis.
For this purpose, it is required to make a correct judgement about the problem by asking the user.
11-2-1. Trouble Analysis Classification
Trouble
analysis
classification
Totally
inoperable
Some parts are
inoperable.
Operable but
abnormal.
1 Unit is inoperable.
2 Breaker or fuse blows out.
3 Only fan does not work.
5 Compressor does not operate.
6 Unit repeats ON/OFF frequently. Short cycles.
7 Cooling is not obtained or insufficient.
8 Drying is not obtained or insufficient.
9 Water leaks.
10 Abnormal noise.
4 Compressor does not operate.
(Fan is also inoperable.)
a No power turns on.
c All relays do not work.
At cooling and drying operations,the
compressor works,but the fan does not run.
Lamp flashes.