8. MICROCOMPUTER BLOCK DIAGRAM
Fig. 8-1
Functions
3-minute delay at Restart for
compressor
Start-up Compensation for fan
motor
Timer
Processing
(Temperature processing)
Clock frequency oscillator circuit
Initializing circuit
C.P.U.
Mode selector
(Cool/Dry/Fan only)
Operation indicator
Economy indicator
Economy indicator
Warning indicator
Timer selector (ON,
CONTINUE, OFF)
Timer setting
Air flow selection
(Fan selector High,
Low, AUTO)
Operation
(ON/OFF)
Temperature setting
Economy selection
(ON/OFF)
Room temperature sensor
(Ta sensor)
Power supply
circuit
Relay driver
Miniature
relay
Relay driver
Transformer
Power relay
Heat-exchanger sensor
(Tc sensor)
AC input
DC 12 volt
DC 5 volt
Compressor ON/OFF signal
Fan motor signal
Compressor
Fan motor
Control unit
Remote control unit
AC 50Hz
220/230/
240V
A bold line denotes a 220/230/240V AC line.